Technical data Functions
e-drive or interface
Temperature/air volume diagram
4
3.5
3
2.5
2
1.5
1
0.5
0
0
Interface / activation
Air volume
GND
0 - 10 V
Blower capacity f (control voltage)
100
90
80
70
60
50
40
30
20
10
0
0
CAUTION:
When using the device as a built-in unit, a suitable mechanism for disconnecting all poles from the mains with
a contact space of at least 3 mm must be present in the power supply cord.
16
Air volume
100
200
300
Air volume l/min
Input 0 – 10 V
Alarm contact
COM NO
4
6
2
Voltage [V]
Air volume specification 1, 5...100%;
5% resolution
400
500
Air volume
+ 4 - 20 mA
– 4 - 20 mA
100
90
80
70
60
50
40
30
20
10
0
8
10
600
700
Input 4 – 20 mA
Blower capacity f (control current)
4
12
8
Current [mA]
Alarm contact
COM NO
16
20