Display description
Symbols
Undervoltage
Standby
Indicator field for displaying units or information for the service menu
Field for displaying the target and actual values.
This is a four-digit segment display without decimal points.
The bar display symbolizes the blower speed at 5 levels.
At the same time, it appears in % (1 P–100 P)
Blower speed 100% max.
Tool protection function
If the device overheats (air intake temperature is too warm or warm air back pressure), the motor is switched off
while at the same time the work contact of the alarm relay opens. If the tool protection signals, the following steps
should be carried out to reset the device for safety reasons:
MONO SYSTEM
A Let the device cool
B Disconnect the power cord from the mains
C After 10 seconds, plug the device into the mains again
D Check air intake, air output opening and clean if necessary.
Operation
Switch on the mains
Increase air volume in %
turn e-drive to the right
18
Stand-by mode
Bar display flashes as long as the value is being set.
Press e-Drive for 5 seconds
Return to Standby mode
The last settings for the values are saved.
Symbols
Contact a Leister service center
Active blower
Blower speed 1 % min.
e-Drive
Press 3 seconds
Reduce air volume in %
turn e-drive to the left