Descargar Imprimir esta página

Important; Electrical Safety - Jacuzzi PLAY SPHERE TB Serie Manual De Instrucciones

Publicidad

WARNINGS
• All measurements are in centimetres
• The drawings given are not to scale
Info
PLAY shower enclosures are equipped with an integrated show-
er tray unit, which is in direct contact with the floor and the
drainage column inserted in the floor.
Installation must take place in a corner on finished and tiled
walls, but without skirting and/or projecting parts.
IMPORTANT: check that the goods are intact on arrival, so
that any claim made to the forwarding agent will be prompt.
Provision for drainage
and water supply connections
We recommend that you position the shower enclosure drain as
shown, in position 1 or 1a.
To connect to the hot-cold water supply system (position 5), it is
advisable to use 90° curves - 1/2".
Please use the measurements given.
We also recommend that you do not use connections on supply
pipes, in order to avoid leaks and consequential reduction in wa-
ter jet power.
For correct water jet operation, the pressures and capacities of the
water supply system to the shower enclosure must be ensured,
as shown in the "Plumbing Requirements" table.
Provision for electrical connection
For all models equipped with electronic functions, a standard ca-
ble must be used for connections to the electrical mains and the
earth system, and prepared as shown in position 2.
The device can be powered with a double phase line, providing
that the voltage between phases is 220-240V.
If you wish to connect the shower enclosure to an alarm circuit,
a bipolar cable must be used (position 2).
In any case, see the "Electrical Safety" chapter to choose the ca-
bles and installation procedures.

Electrical safety

Jacuzzi
®
PLAY TT shower enclosures are safe appliances, manu-
factured in compliance with CEI EN 60335-1, CEI EN 60335-2-
105; EN 61000; EN 55014 norms and approved by the SIQ Cer-
tification Institute. They are tested during production to guar-
antee user safety. Installation must be carried out by qualified and
authorized personnel, in compliance with the national provisions
in force.
It is the responsibility of the installer to choose the ma-
terials with regard to their use, to carry out the work
correctly, to check the condition of the system to which
the appliance is to be connected and its suitability in or-
der to guarantee user safety.
PLAY shower enclosures are Class "I" appliances, and must be an-
chored securely and connected permanently, without any inter-
mediate joints, to the electric network and earth system.
The electric network and earth system of the building
must be in working order and must comply with the
provisions of the law and specific regulations in force in
that country.
For connection to the electric mains, it is necessary to install a dis-
connecting multiple-pole switch, and place it in an area that com-
plies with the safety prescriptions for bathrooms. This standard
multiple-pole switch must guarantee a contact opening of at
least 3mm and be suitable for voltages of 220-240V and currents
up to 16A.
The switch and other electrical devices must be located, in
accordance with regulations, in an area that cannot be
reached by the person using the appliance.
The installation of electrical devices and appliances (sockets,
switches, etc.) in bathrooms must comply with the legal re-
quirements and standards of the country concerned. In particu-
lar, no electrical installation is permitted within 60 cm of the
shower enclosure or at a height of less than 225 cm.
0,6 m
Connection to the electrical system of the building must be made us-
ing a sheathed cable that is not less than H 05 VV-F 3x2,5 mm
The appliance must be powered by a differential cir-
cuit breaker; the operating current must not exceed
30mA.
Jacuzzi
®
PLAY shower enclosures are equipped with a connection
terminal, located in the upper part of the column, marked with the
symbol
, for equipotential connection of surrounding metal parts,
as required by CEI EN 60335-2-105 norms; we recommend that the
relevant connection cable comes out in position 2.
9
0,6 m
2
.

Publicidad

loading