1. Press the EMERGENCY STOP switch.
▶ Emergency stop is triggered.
If the drilling system is not connected or not paired, the auto-feed unit automatically initiates an
attempt to connect or pair.
→ Wait until this process has completed.
2. Reset the EMERGENCY STOP switch by pulling it up.
▶ The drilling system changes to the Position CUT ASSIST mode.
▶ The test is successfully completed and the drilling system is ready for use.
4

Technical data

4.1

Product properties

Weight, ready for use
Dimensions (L × W × H)
Max. permissible water supply pressure
Protection class
Protection class
4.2
Bluetooth
Frequency band
Maximum emitted transmission power
4.3

Rated voltage

Rated voltage
Rated frequency
Rated current input
4.4
Noise and vibration values
The auto-feed unit is a system product and is operated exclusively in combination with a diamond core
drilling machine. The operating noises of the auto-feed unit are minor and do not contribute to a relevant
increase in the acoustic emissions of the overall drilling system.
The acoustic emissions and vibration emissions of the diamond core drilling machine used apply.
Also study and follow all instructions relating to safety and operation in the corresponding operating
instructions of the system products (diamond core drilling machine, drill stand).
5

Preparations at the workplace

CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Installing the auto-feed unit 3,
WARNING
Risk of injury! The drill stand can rotate or topple if not securely fastened.
▶ Before using the drilling system, always secure the drill stand to the surface of the material to be drilled
with an anchor.
▶ Use only anchors suitable for the base material and comply with the anchor manufacturer's instructions.
20
English
110 V ... 120 V
50 Hz ... 60 Hz
0.6 A
2
4.2 kg
176 mm x 137 mm x 325 mm
≤ 6 bar
Protection class II
IP 55
2,400 MHz ... 2,483 MHz
10 dBm
220 V ... 240 V
50 Hz ... 60 Hz
0.4 A
2299964