Wiring the Inverter
Magnetic
Contactor
L1
3-phase power
L2
380 to 480V
50/60Hz
L3
PE
Forward run/stop
Reverse run/stop
Nominal Speed
Inspection Run
Multi function
Inputs
Intermediate Speed
(Factory setting)
Leveling Speed
Not used
Hardware Baseblock (note 3)
Analog input
(Speed reference)
2kOhm
Optional control power
supply input for Rescue
Operation
Note:
1. Main circuit terminals are indicatied with double circles and
control circuit terminals are indicatied with a single circles
2. The CN5 factory setting is NPN
3. To enable the inverter both inputs, BB and BB1 must be closed. If
only one of the inputs is closed, "BB" will be displayed in the
operator panel and the inverter will not start.
DC reactor to improve input
power factor (optional)
Link
(+1)
(+2)
L1(R)
Line
L2(S)
Filter
L3(T)
S1
S2
S3
S4
S5
S6
S7
BB
BB1
+24V, 8mA
SC
CN5(NPN setting)
E(G)
Voltage adjust-
ment
+V
Analog input power
supply +15V, 20mA
2kOhm
0 to 10 V
A1
Master speed
reference 0 to 10V
P
AC
0 V
Input option cards
2CN
to terminal B1
P0
Control Power
Supply Input
to terminal -
N0
Shielded
wires
Fig 4 Wiring Diagram
Braking Resistor
unit (optional)
(-)
B1
B2
U/T1
V/T2
W/T3
TA1
PG-X2
(Optional)
TA3
TA2
A Pulse
B Pulse
Z Pulse
IP24V (24V)
MA
Fault contact output
MB
250VAC, max. 1A
30VDC, max. 1A
MC
M1
Brake Command
M2
(Factory setting)
M3
Contactor Control
M4
(Factory setting)
M5
Inverter Ready
M6
(Factory setting)
Output option
3CN
cards
Twisted-pair
wires
Motor
IM/PM
PG
P
P
Pulse Monitor Output
RS-422
(100m or less)
Multi-function
contact output
250VAC, max. 1A
30VDC, max. 1A
EN-10