14/40 Bosch Rexroth AG | Electric Drives and Controls
5 Initial Operation
5.5
Motor contactor control
Operation of the ErgoSpin hand-
held nutrunner with the LTU350 is
permissible only in setting 2 (see
Fig. 3)!
Switch
Explanation
setting
*
0
no motor contactor control
*
1
24 V signal PS from supply module
Engaging motor contactor control via
the ErgoSpin start switch (factory set-
2
ting) guarantees personnel safety
when operating the ErgoSpin hand-
held nutrunner with the LTU350!
permanent 24 V signal PS from the
*
3
motor contactor (not an emergency-
off switch)
Table 9:
Rotary switch positions in the LTU
*
Not permissible for hand-held nutrun-
ner operation!
1
W
OK
571.33
M
35.10
Reset
X3
X2
LTU350
Figure 3:
Rotary switch in pos. 2
1
Protection class plug on slot A
2
2
B
A
LTU350 | 3 609 929 961/1.1
5.6
Protection class plug
The protection class plug on slot A ensures
the protective grounding of the hand-held nu-
trunner (see Fig. 3).
The plug position may not be
changed! Otherwise this affects
the electrical safety.
5.7
Fuses
The servo amplifier's intermediate circuit is
protected by two fuses. Should the fuses
blow, the BTB LED changes from green to
red. The system is not operable in this condi-
tion. The fuses are located on the back of the
servo amplifier and must be exchanged in the
case described above. (For removal, please
see Fig. 4).
Caution: The safety instructions in
Chapter 3 (see page 11) must be
observed!
W
OK
571.33
M
35.10
Reset
X3
X2
LTU350
Figure 4:
Fuse removal