ABB-Welcome
4.2.3

Time relay

Fig. 4:
Release a lock
No.
Functions
1
2->ON, 3->OFF
Pos : 74 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Master/Sl ave Schalter s etz en 83220-AP- xxx @ 19\mod_1310723320966_15.doc x @ 107833 @ @
The device is enabled by pressing the program button on indoor stations/guard units or
a light button on outdoor stations in the same sub-system which releases a connected
lock or switches on the light.
The device is disabled after a customized time-out (ranging from 1 second to 5 minutes).
If an indoor station/a guard unit is used to control the switch actuator, the address of the
program button is equal to that of the switch actuator, which can be set from 001 to 199
in the same sub-system.
Pos : 75 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okument ation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
1
DIP
2 3
Programming first!
— 8 —