Residual Risks; Technical Data - Würth DCN 4590 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
Property damage:
Do not use the air nailer in the rain or in very
damp surroundings.
Do not expose the air nailer to high tempera-
tures, e.g. direct sunlight.
Only use the air nailer outdoors or in well ven-
tilated areas at temperatures between -10°C
and 40°C.
Do not use the air nailer with an empty mag-
azine.
Only store the air nailer in dry, frost-free rooms.
Stop work immediately in the following
situations:
If the hose is visible damaged.
If screws or other parts have come free or
fallen from the device.
Art.
Working pressure
Air consumption per cycle (at 7 bar)
Air connection
Weight
Staple width / penetration depth
Nail diameter / penetration depth
(wire-welded coil nails)
Nail diameter / penetration depth (coil nails
on plastic tape)
Compressed air lubricant
Trigger system
22
Safety instructions

Residual risks

In spite of observation of the applicable safety
regulations and the
Use of protective devices, certain risks
cannot be avoided. These include:
Damage to hearing.
Risk of injury due to projectile parts.
Risk of burns due to accessories becoming hot
during operation.
Risk of injury due to persistent use. Intended
use
The nailer is intended solely for connection to a
standard compressed air compressor and for the
firing of nails and staples (hereinafter referred to
as fasteners) supplied by Würth.
The user is responsible for damage resulting from
improper use.

Technical data

DCN 4590
0703 558 0
5 - 8 bar
2.97 l
1/4"
3.6 kg
-
2.5-3.8 mm / 45 mm
2.5-2.9 mm / 45-75 mm
Single trigger
DKG 416
0703 548 0
4.2 - 7 bar
0.34 l
1/4"
0.7 kg
12.8 mm / 4-16 mm
-
-
Art. no. 0893 0505