8.1
CHARACTERISTICS AND INTERPRETATIONS
Ref.
L – N
SINGLE-PHASE
R – S – T
THREE-PHASE
U - V – W
THREE-PHASE
R – S
SINGLE-PHASE
Power supply terminal: + 12V DC – 50Am.
1
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
Connection terminal of input i3 for general disabling command.
2
=IN 3
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
Connection terminal of input i2 for selecting set point 1.
3
=IN 2
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
J22
Common connection terminal I
4
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
Connection terminals of input i1 for protection against dry running.
6
=IN 1
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
Connection terminal: 0V DC (GND).
7
(excluding A.D. M/M 1.1 and A.D. M/T 1.0)
Remote alarm connection terminal. (excluding A.D. M/M 1.1 and A.D. M/T 1.0)
o1
250 Vac – 6 A max resistive load – 3 A max inductive load
J14
Pump operating connection terminal. (excluding A.D. M/M 1.1 and A.D. M/T 1.0)
o2
250 Vac – 6 A max resistive load – 3 A max inductive load
Connection terminals for interconnection and exchange.
ATTENTION: For interconnection cables with a length of more than 1 m, it is
J9
recommended to use screened cable with the braiding connected to earth (central pin
number 2) on both appliances. ATTENTION: Scrupulously respect the connection
sequence between the two appliances! (excluding A.D. M/M 1.1) (see fig.2)
ACTIVE DRIVER M/T 2.2
Primary
Active Driver
For functionality and programming:
see table on page 49 "Assigning the parameters that associate functions with the digital outputs OUT1, OUT2"
ENGLISH
Power supply line connection terminals.
Line earth system connection terminal.
Three-phase pump connection terminals.
Pump earth system connection terminal.