7
COMMISSIONING
12
WTS26 x-xxxxxx3 xAxx with teach-in button:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). We recom‐
mend placing the sensing range in the object, e.g.
has been adjusted, the object is removed from the path of the beam, which causes the
background to be suppressed and the switching output to change
table
4).
1
1...3 sec.
2
Figure 6: WTS26x-xxxxxx3xAxx, adjusting the sensing range with teach-in button
4
Detection of flat, glossy, contrast-rich, and uneven objects
If the objects are detected from above, we recommend installing the sensor at an angle in
order to prevent total reflection by a reflective surface
1
When adjusting the sensing range, the light spot should be focused on an even, uni‐
form surface, e.g. a white sheet of paper.
1...3 sec.
Figure 7: Sensing range setting
see figure
6. Once the sensing range
(see table