3
COMMISSIONING
2
The minimum distance (= y) for background suppression can be determined from
diagram [H] as follows:
Example: x = 100 mm, y = 7 => 7 % of 100 mm = 7 mm. That is, the background is
suppressed at a distance of > 107mm from the sensor.
% of sensing distance
25
6 %/90 %
20
15
10
18 %/90 %
5
90 %/90 %
0
mm
25
50
75
100
125
(inch)
(0.98)
(1.97)
(2.95)
(3.94)
(4.92)
Distance in mm (inch)
Image: H
2
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of 0.8 Nm.
Note the preferred direction of the object relative to the sensor [see A].
3
The sensors must be connected in a voltage-free state (V
in the graphics [B] must be observed, depending on the type of connection:
–
Male connector connection: pin assignment
–
Cable: core color
Image: B
Only apply voltage/switch on the power supply (V
tions have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching outputs Q and /Q (according to Graphic B):
Teach-in = external teach-in (ET) (see Adjustment)
WTB4-3Exxxx and WTB4-3Fxxxx
D: dark-switching, output (Q) switches off when an object is present in the sensing
range.
WTB4-3P1362 and WTB4-3Px1xx
WTB4-3N1362 and WTB3Nx1xx
L: light switching, output (Q) switches when an object is present in the sensing ran‐
ge.
WTB4-3P1162 and WTB4-3N1162
WTB4-3Px262 and WTB4-3Nx262
ANT: complementary outputs Q and Q/
WTB4-3Pxxx4 and WTB4-3Nxxx4
L: light switching, output (Q) switches when an object is present in the sensing ran‐
ge. In addition: ET: teach-in function via cable.
Connect ET cable (PIN 2) to U
Connect ET cable (PIN 2) to M for > 2 s (NPN output)
150
(5.91)
> 0 V) once all electrical connec‐
S
for > 2 s (PNP output)
V
= 0 V). The information
S
8011166.126R | SICK