6. Commissioning, operation
Status switching output 2
Status switching output 1
Display mode
EN
▶ Short press
Display of the unit
▶ Long press
Display of the set parameters
see chapter 6.6 "Parameters"
Programming mode
▶ Short press
Menu up
Parameter value up (step-wise)
▶ Long press
Menu up
Parameter value up (fast)
6.6 Parameters
Parameter
Description
SP1/SP2
Hysteresis function: Switch point switching output (1 or 2)
FH1/FH2
Window function: Window high switching output (1 or 2)
RP1/RP2
Hysteresis function: Reset point switching output (1 or 2)
FL1/FL2
Window function: Window low switch output (1 or 2)
EF
Extended programming functions
RES
Return the set parameter to the factory settings
DS1/DS2
Switch delay time, which must occur without interruption before any electrical signal change occurs (SP1 or SP2)
DR1/DR2
Switch delay time, which must occur without interruption before any electrical signal change occurs (RP1 or RP2)
14
4-digit LED display
Display pressure value
■
Display menu item
■
Display parameter
■
Display mode
▶ Short press
Display of the unit
▶ Long press
Jumping into the programming mode
Programming mode
▶ Short press
Menu down
Parameter value down (step-wise)
▶ Long press
Menu down
Parameter value down (fast)
Display mode
▶ Short press
Display of the unit
Programming mode
▶ Short press
Select menu item
Confirmation of the input
Pressure sensor SPAW