6. Commissioning, operation
Parameter
Description
OU1
Switching function switching output (1 or 2)
OU2
HNO = hysteresis function, normally open
HNC = hysteresis function, normally closed
FNO = window function, normally open
FNC = window function, normally closed
UNIT
Changing units
(If the measuring range is outside the indication range, a unit switching is not possible and the UNIT parameter is not
indicated)
0SET
Offset adjustment (3 % FS)
DISM
Display value in display mode
ACT = actual pressure value; LOW, HIGH = minimum, maximum temperature value; SP1/FH1 = function switch point 1;
RP1/FL1 = function reset point 1; SP2/FH2 = function switch point 2; RP2/FL2 = function reset point 2;
OFF = display off
DISU
Display update 1, 2, 5, 10 updates/second
DISR
Rotate display indicator by 180°
RHL
Clear the Min- and Max-value memories
PAS
Password input, 0000 = no password
Password input digit by digit
TAG
Input of a 16-figure alphanumeric measuring point number
Pressure sensor SPAW
EN
15