The Troubleshooting table indicates measures to be taken if the sensor stops working.
LED indicator/fault pattern
Green LED flashes
Switching outputs do not
behave in accordance with
table 4
WTS only: yellow LED flashes
quickly
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
PROCESS DATA STRUCTURE
A71
A72
V1.1
2 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Q
/ Boolean
L1
/ Boolean
Qint.1 /
Boolean
2 ...15 /
2 ... 15 /
2 ... 15 /
[counter
[length /
value] /
speed
value] /
UInt 14
measure‐
UInt 14
ment] /
SInt14
Cause
IO-Link communication
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
When adjusting the sensing
range, the light spot is only
half on the object or on a very
high-contrast object
The sensing range distance is
too large
Distance between the sensor
and the object is too long or
sensing range is set too short
A73
A75
4 bytes
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Q
/
Qint.1 / Boolean
L2
Boolean
2 / Qint.
2 ... 7 / [empty]
1 /
Boolean
3 ... 15 /
8 ... 31 / [carrier
[time mea‐
load] / UInt 24
surement
value] /
UInt13
Measures
None
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
Sensing range setting accord‐
ing to Section "Sensing range
setting for WTS16".
Reduce the sensing range
Increase the sensing range
8
15