7
COMMISSIONING
12
WTL16 x-xxxxxx3 xAxx, WTS16 x-xxxxxx3 xAxx with teach-in button:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.). We recom‐
mend placing the sensing range in the object, see figure 9 for an example. Once the sens‐
ing range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change
table 3
and
table
4).
1
1...3 sec.
2
Figure 6: WTL16x-xxxxxx3xAxx, WTS16x-xxxxxx3xAx red light, adjusting the sensing range
with teach-in button
4
Sensing range setting WTS16
Detection of flat, glossy, contrast-rich, and uneven objects.
If the objects are detected from above, we recommend installing the sensor at an angle in
order to prevent total reflection by a reflective surface
1
When adjusting the sensing range, the light spot should be focused on an even, uni‐
form surface, e.g. a white sheet of paper.
(see table
2,
8020347.14CS | SICK