Door switch
The door switch refers to the switch on the sauna door. This switch com-
plies with regulations. Public and private saunas must have a door switch,
i.e. saunas where the heater can be switched on from outside the sauna,
e.g. using an On/Off button or a similar method.
For additional information about door switch. www.tylohelo.com
Remote controlling
The Heater can be remotely controlled by connecting a closed contactor,
which can be pulse triggered, to connectors 3 and 4 of a RJ10 circuit board.
The recommended cable size is AWG 24 or 26. The maximum length of an
AWG 24 cable is 200 m when using a Pure controller. The maximum length
of an AWG 26 cable is 130 m when using a Pure controller
Principle coupling when Pure is used
as control panel
Heater
Sensor cable
1 = Blue
OLEA 99
2 = White
3 = Red
4 = Yellow
Heater
Apter circuit board
OLEA 99
Sauna heater's
Power
connection cable
H07RN –F/ 60245
IEC 66
mm²
kW
400V 3N~
6,8
5 x 1,5
10,5
5 x 2,5
Table. Connection cable and fuses
Connection of the sauna heater to the mains
The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. The
sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type.
Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC
insulated cable as a connection cable for the sauna heater.
Helo-WT technology in a Himalaya heater
Helo-WT uses the heater's thermal energy to heat water and raise the moisture level without a separate heat source.
Moisturised air improves the sauna climate, and various fragrances and salts can be evaporated to make the sauna experience
more enjoyable.
For additional information about Helo-WT :
Terminal block
4
3
2
1
Sensor OLET 31
A1 Yellow
A2 Green
A3 Red
A4 Black
Sauna heater's
Fuse
connection cable
H07RN –F/ 60245
A
230V 3~
3 x 10
3 x 16
www.tylohelo.com
Limiter
Control panel
pure
Fuse
IEC 66
mm²
A
4 x 4
3 x 20
4 x 6
3 x 35
Door switch
Min. 300 mm
Magnet on
the door
Door switch
position when
installed on
lower part of the
door
Sauna heater's
Fuse
connection cable
H07RN –F/ 60245
IEC 66
mm²
A
230V 1 N~ / 2~
3 x 6
1 x 35
----------
--------
3
Junction box