Troubleshooting - Milwaukee M18 BPFP-CST Manual Original

Ocultar thumbs Ver también para M18 BPFP-CST:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
• After each use, check all parts of the product for leaks. Return the
product to an authorised service center for repair, if it has any.
• The spray wand can be stored in the cradle.
• For transportation, secure the product against movement or falling to
prevent injury to persons or damage to the product.
• Store the product in a cool, dry and well-ventilated place that is
inaccessible to children. Keep away from corrosive agents such as
garden chemicals and de-icing salts. Do not store outdoors.
RESIDUAL RISKS
Even when the product is used as prescribed, it is still impossible to
completely eliminate certain residual risk factors. The following
hazards may arise and the operator should pay special attention to
avoid the following:
Electric shock. Never spray liquid towards electrical sockets, cables, or
appliances.
Contact with hazardous substances. Spray materials may be harmful if
inhaled, ingested, or comes in contact with skin or eyes. Follow
instructions carefully and wear appropriate protective equipment as
prescribed in this manual.

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
SOLUTION
Low pressure
Not enough battery
Charge the battery
charge
No pressure
Not enough battery
Charge the battery
charge
Leaky
Connections are not
Retighten connecting
connected properly,
elements, replace sealing
gaskets porous
elements
Motor is not
Battery empty or
Recharge or replace the
running
defective
battery
No spray
Spray nozzles are
Clean with compressed air
blocked
or a suitable solvent
BLOCKED NOZZLES
If the nozzles are blocked, immediately turn off the sprayer.
Ensure the battery door is closed securely.
Wear protective clothing such as gloves and eye protection.
Disassemble the nozzles and clean with clear water. Replace defective
fi lters.
CLEANING THE TANK
1. Ensure the battery door is closed securely.
2. Remove the tank from the base and set on a level surface away
from the base to prevent exposing the base to harsh chemicals.
3. Remove the tank cup and fi ll it about one-third full with clean water.
A small amount of mild household detergent may be added. If
needed warm water (max. 50°C) can be used.Replace the cap and
gently slosh the water around the tank.
4. Install the tank and spray the water until the tank has been emptied.
Make sure to direct the spray toward an area that will not be
damaged by residue chemicals in the tank.
5. Repeat the procedure with clean water until the tank is thoroughly
clean. Wash outside of nozzles and dry with cloth.
6. Wipe the outside of the tank with a clean, dry cloth.
7. Allow all pieces to completely dry before reinstalling parts and
storing the unit. Always reinsert strainer before replacing tank cap.
44
ENGLISH
MAINTENANCE
Servicing requires extreme care and knowledge and should be
performed only be a qualifi ed service technician. For service we
suggest you return the product to an authorized service center for
repair. When servicing, use only identical replacement parts.
Only make adjustments or repairs described in this manual. For other
repairs, contact an authorised service centre.
After each use, clean the product as prescribed in this manual.
Drain and empty the spray tank before cleaning.
Drain the spray materials through the fi ll area.
Drain all of the spray materials from the spray tank into a container
approved for chemicals. Do not store chemicals in the spray tank.
Use clean water to clean and rinse the spray tank. A small amount of
mild household detergent may be added.
Wipe the product with a clean, dry cloth.
It may be necessary to rinse the spray tank more than once.
Cleaning electrical contacts
Keep electrical contact posts between bottom of tank and base clean.
WARNING! Remove battery pack from tool before cleaning electrical
contacts. Clean contacts with a dry, clean cloth only.
Tank
Contacts
Base
Disposal
Never dispose residual chemicals or contaminated rinsing solutions in
waterways, drains, sewers, street gutters, or manholes.
Dispose residual chemicals and used containers in accordance with
local waste disposal regulations.
ACCESSORIES
Use only Milwaukee accessories and spare parts. Should components
need to be replaced which have not been described, please contact
one of our Milwaukee service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered. Please state
the machine type printed as well as the six-digit No. on the label and
order the drawing at your local service agents or directly at: Techtronic
Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Please read the instructions carefully before starting the
machine.
Remove the battery pack before starting any work on
the machine.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end of
their life must be collected separately and returned to
an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
Always wear eye protection!
Wear ear protectors!
Wear a suitable protection mask.
Use protective clothing
Wear gloves!
Wear sturdy non-slip shoes!
Do not expose battery to rain. Do not use battery in
damp or wet locations.
Do not spray fl ammable liquids
Class III electrical protection.
Remove the battery pack.
Keep electrical contacts clean.
Keep bystanders a safe distance away from work area!
Do not spray at people or animals!
Do not spray at a wall!
Do not spray against the wind!
Do not point the nozzle upwards! Only spray
downwards!
Empty weight (including baseunit, tank,
battery)
V
Volts
Direct current
European Conformity Mark
Ukraine Conformity Mark
EurAsian Conformity Mark
ENGLISH
45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M18 bpfp-ccstM18 bpfp-wstM18 bpfph

Tabla de contenido