9"
(22.9 cm) -
9-1/4"
(23.5 cm)
4. Install the Finished Ceiling
Install the water-resistant wall board.
Cut out a 9" (22.9 cm) to 9-1/4" (23.5 cm) square at the desired
installation location.
Install the finished ceiling material.
5. Install the Pipe Nipple
Remove the nipples.
NOTE: The minimum distance between the face of the tees/elbows
and the surface of the finished ceiling should be 2-1/4" (5.7 cm). The
measurement for typical installations is 2-3/4" (7 cm).
Measure the distance from the face of the tees/elbows to the
surface of the finished ceiling. Make any adjustments as needed.
If your measurement is 2-1/4" (5.7 cm): Use close pipe nipples.
If your measurement is 2-3/4" (7 cm): Use 1-1/2" pipe nipples.
Thread the nipple into the tee/elbow and hand tighten.
Kohler Co.
Finished Ceiling
Cutout
Finished
Ceiling
Cutout
Tee
9" (22.9 cm) -
Nipple
9-1/4" (23.5 cm)
7
Tee
2-1/4"
(5.7 cm)
Min
9"
(22.9 cm) -
9-1/4"
(23.5 cm)
1057619-2-E