1. Text colour (Low = Yellow, Pass = Green, High = Red)
2. Target icons (Low =
3. Target indicator line
Example
Target 1 (T01) Set to 200.0 N·m ±3% (194.0 – 206.0 N·m)
Mode set to Click
First Reading 190.7 N·m (LOW)
Clockwise
Second Reading 202.1 N·m (PASS)
In tolerance band
Third Reading 212.4 N·m (HIGH)
Above tolerance band

4.10 Using the Instrument

1. Select mode of operation
2. Select target
3. Select units
4. Place torque screwdriver / torque wrench in the input drive and operate in the desired direction
5. Remove the torque screwdriver / torque wrench and zero the display (if required) by pressing
the RESET button
6. Place the torque screwdriver / torque wrench in the input drive and operate in the desired
direction
ü
, Pass =
, High =
Low
Below
tolerance band
Pass
High
)
The target indicator line is
scaled to show ±20% centred
on the target value (200 N·m)
The 2 lines closest to the
centre line indicate the
argets tolerance band (±3%)