  • Página 1 Honda EG3600CL·EG4500CL EG5500CL OWNER’S MANUAL Original instructions MANUEL DE L’UTILISATEUR Notice originale BEDIENUNGSANLEITUNG Originalbetriebsanleitung MANUAL DE EXPLICACIONES Manual original The‘‘e-SPEC’’mark symbolizes environmentally responsible technologies applied to Honda power equipment, which contains our wish to ‘‘preserve nature for generations to come.’’...
  • Página 2 11/04/26 16:08:40 32Z30600_002...
  • Página 3 All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation.
  • Página 4: Tabla De Contenido

    ............52 13. WIRING DIAGRAM ................55 SWITCH CONNECTIONS ..............56 RECEPTACLE ..................56 MAJOR Honda DISTRIBUTOR ADDRESSES ....inside back cover ‘‘ EC Declaration of Conformity ’’ CONTENT OUTLINE ..inside back cover...
  • Página 5: Safety Instructions

    11/04/26 16:09:10 32Z30600_005 SAFETY INSTRUCTIONS IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator.
  • Página 6 11/04/26 16:09:19 32Z30600_006 Carbon Monoxide Hazards Exhaust contains poisonous carbon monoxide, a colorless, odorless gas. Breathing exhaust can cause loss of consciousness and may lead to death. If you run the generator in an area that is confined, or even partially enclosed area, the air you breathe could contain a dangerous amount of exhaust gas.
  • Página 7 11/04/26 16:09:28 32Z30600_007 Fire and Burn Hazards Do not use the generator in areas with a high risk of fire. The exhaust system gets hot enough to ignite some materials. − Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during operation.
  • Página 8 Do not throw it in the trash or pour it on the ground. An improperly disposed battery can hurt the environment. Always confirm local regulations for battery disposal. Contact your Honda servicing dealer for a replacement.
  • Página 9: Safety Label Locations

    These labels warn you of potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in this manual carefully. If a label comes off or becomes hard to read, contact your Honda dealer for a replacement. READ OWNER’S MANUAL...
  • Página 10 11/04/26 16:09:54 32Z30600_010 Honda generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage.
  • Página 11 11/04/26 16:10:00 32Z30600_011 A hot exhaust system can cause serious burns. Avoid contact if the engine has been running. Gasoline is highly flammable and explosive. Turn the engine off and let it cool before refueling.
  • Página 12: Ce Mark And Noise Label Locations

    11/04/26 16:10:11 32Z30600_012 CE mark and noise label locations NOISE LABEL AND CE MARK NOISE LABEL Performance class Quality class IP code Dry mass Year of manufacture Manufacturer and address Name and address of authorized representative [Example: EG5500CL (BT type)]...
  • Página 13: Component Identification

    11/04/26 16:10:19 32Z30600_013 COMPONENT IDENTIFICATION FUEL GAUGE CONTROL PANEL CHOKE LEVER FUEL VALVE LEVER OIL FILLER CAP STARTER GRIP SEDIMENT CUP AIR CLEANER OIL DRAIN BOLT ENGINE SERIAL NUMBER FUEL TANK CAP SPARK PLUG FRAME SERIAL NUMBER MUFFLER Record the frame serial number and the engine serial number in the spaces below.
  • Página 14 11/04/26 16:10:25 32Z30600_014 CONTROL PANEL EG3600CL: BT type ENGINE SWITCH 230V RECEPTACLE AC CIRCUIT PROTECTOR AC CIRCUIT BREAKER 115V RECEPTACLES VOLTAGE SELECTOR SWITCH GROUND TERMINAL EG3600CL: FT type ENGINE SWITCH 230V RECEPTACLES AC CIRCUIT BREAKER GROUND TERMINAL EG3600CL: ITT type...
  • Página 15 11/04/26 16:10:31 32Z30600_015 EG3600CL, EG4500CL, EG5500CL: GT, GWT types ENGINE SWITCH AC CIRCUIT PROTECTORS * * AC CIRCUIT BREAKER 230V RECEPTACLES * : Except EG3600CL GROUND TERMINAL EG4500CL, EG5500CL: BT type ENGINE SWITCH 230V RECEPTACLE AC CIRCUIT PROTECTORS 115V RECEPTACLES...
  • Página 16 11/04/26 16:10:36 32Z30600_016 EG4500CL, EG5500CL: FT type ENGINE SWITCH AC CIRCUIT PROTECTORS AC CIRCUIT BREAKER 230V RECEPTACLES GROUND TERMINAL EG4500CL, EG5500CL: ITT type ENGINE SWITCH AC CIRCUIT PROTECTOR 230V RECEPTACLES AC CIRCUIT BREAKER GROUND TERMINAL...
  • Página 17 If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON. EG3600CL: BT type EG4500CL, EG5500CL: GT, GWT types AC CIRCUIT PROTECTOR...
  • Página 18 11/04/26 16:10:47 32Z30600_018 EG4500CL, EG5500CL: BT type EG4500CL, EG5500CL: FT type AC CIRCUIT PROTECTORS AC CIRCUIT PROTECTORS EG4500CL, EG5500CL: ITT type AC CIRCUIT PROTECTOR...
  • Página 19: Pre-Operation Check

    11/04/26 16:10:55 32Z30600_019 PRE-OPERATION CHECK Be sure to check the generator on a level surface with the engine stopped. Check the engine oil level before each use. Using non detergent oil or 2-stroke engine oil could shorten the engine’s service life. Recommended oil: Use 4-stroke motor oil that meets or exceeds the requirements for API service category SE or later (or equivalent).
  • Página 20 11/04/26 16:11:03 32Z30600_020 Remove the oil filler cap and wipe the dipstick clean. Check the oil level by inserting the dipstick in the filler hole without screwing it in. If the oil level is low, fill to the upper limit of the oil filler neck with the recommended oil.
  • Página 21 11/04/26 16:11:14 32Z30600_021 Check the fuel level. Check the fuel gauge. If the fuel level is low, refuel the fuel tank until the level as specified. After refueling, tighten the fuel tank cap securely. Use automotive unleaded gasoline with a Research Octane Number of 91 or higher (a Pump Octane Number of 86 or higher).
  • Página 22 Gasolines Containing Alcohol If you decide to use a gasoline containing alcohol (gasohol), be sure its octane rating is at least as high as that recommended by Honda. There are two types of ‘‘gasohol’’: one containing ethanol, and the other containing methanol.
  • Página 23 11/04/26 16:11:35 32Z30600_023 Check the air cleaner. Check the air cleaner element to be sure it is clean and in good condition. Unsnap the two air cleaner cover clips, remove the air cleaner cover, and remove the air cleaner element. Clean or replace the air cleaner element if necessary (see page Never run the engine without the air cleaner element.
  • Página 24: Starting The Engine

    11/04/26 16:11:44 32Z30600_024 STARTING THE ENGINE When starting the generator after adding fuel for the first time, after long-term storage, or after running out of fuel, turn the fuel valve lever to the ON position, then wait for 10 to 20 seconds before starting the engine.
  • Página 25: Choke Lever

    11/04/26 16:11:51 32Z30600_025 Turn the fuel valve lever to the ON position. FUEL VALVE LEVER Move the choke lever to the CLOSED position to start a cold engine. Move the choke lever to the OPEN position as the engine warms up. CLOSED OPEN OPEN...
  • Página 26: Engine Switch

    11/04/26 16:11:58 32Z30600_026 Turn the engine switch to the ON position. ENGINE SWITCH Pull the starter grip lightly until you feel resistance, then pull the starter grip briskly toward in the direction of the arrow as shown below. The starter grip can be drawn back very quickly before you release it.
  • Página 27 11/04/26 16:12:02 32Z30600_027 Move the choke lever to the OPEN position as the engine warms up. CHOKE LEVER...
  • Página 28: High Altitude Operation

    If you always operate the generator at altitudes higher than 1,500 meters (5,000 feet) above sea level, have your authorized Honda dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 300 meter (1,000 foot) increase in altitude.
  • Página 29: Generator Use

    11/04/26 16:12:17 32Z30600_029 GENERATOR USE The generator produces enough electric power to cause a serious shock or electrocution if misused. Be sure to ground the generator when the connected appliance is grounded. To ground the terminal of the generator, use a cooper wire with same or larger diameter than the cord of the connected appliance.
  • Página 30 Power levels between rated and maximum may be used for no more than 30 minutes. Limit operation requiring maximum power to 30 minutes. Maximum power is: EG3600CL: 3.6 kVA (BT, FT, GT, GWT, ITT types) EG4500CL: 3.68/4.5 kVA...
  • Página 31 11/04/26 16:12:41 32Z30600_031 AC Applications Substantial overloading will switch off the AC circuit breaker. Marginal overloading may not switch off the AC circuit breaker, but it will shorten the service life of the generator. Be sure that all appliances are in good working order before connecting them to the generator.
  • Página 32 AC circuit protector ON (pushing the push button in). EG3600CL: BT type EG4500CL, EG5500CL: GT, GWT types AC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR (For receptacle No.3)
  • Página 33 11/04/26 16:12:53 32Z30600_033 EG4500CL, EG5500CL: BT type EG4500CL, EG5500CL: FT type AC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR (For receptacle No.2) (For receptacle No.2) AC CIRCUIT PROTECTOR AC CIRCUIT PROTECTOR (For receptacle No.3) (For receptacle No.3) AC RECEPTACLE AC RECEPTACLE No.1 No.1 AC RECEPTACLE No.2 AC RECEPTACLE No.2...
  • Página 34 11/04/26 16:13:02 32Z30600_034 Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the Oil Alert system will automatically shut down the engine (the engine switch will remain in the ON position).
  • Página 35: Stopping The Engine

    11/04/26 16:13:10 32Z30600_035 STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch to the OFF position. IN NORMAL USE: Switch off the connected equipment and pull off the inserted plug. Turn the AC circuit breaker to the OFF position. FT, GT, GWT, ITT types BT type AC CIRCUIT BREAKER...
  • Página 36 11/04/26 16:13:13 32Z30600_036 Turn the fuel valve lever to the OFF position. FUEL VALVE LEVER...
  • Página 37: Maintenance

    Be careful not to touch the muffler while it is hot. Let the engine cool before maintenance. Use Honda Genuine parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator.
  • Página 38: Maintenance Schedule

    These items should be serviced by your servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to the Honda shop manual for service procedures. For commercial use, log hours of operation to determine proper maintenance intervals.
  • Página 39: Changing Oil

    11/04/26 16:13:45 32Z30600_039 CHANGING OIL Drain the oil while the engine is still warm to assure rapid and complete draining. Remove the oil drain bolt and sealing washer, remove the oil filler cap, and drain the oil. Reinstall the drain bolt and new sealing washer. Tighten the bolt securely.
  • Página 40: Air Cleaner Service

    11/04/26 16:13:59 32Z30600_040 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.
  • Página 41 11/04/26 16:14:09 32Z30600_041 FUEL SEDIMENT CUP SERVICE Gasoline is extremely flammable and is explosive under certain conditions. Do not smoke or allow flames or sparks in the area. The sediment cup prevents dirt or water that may be in the fuel tank from entering the carburetor.
  • Página 42: Spark Plug Service

    11/04/26 16:14:20 32Z30600_042 SPARK PLUG SERVICE Recommended spark plug: BPR5ES (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
  • Página 43 11/04/26 16:14:27 32Z30600_043 Make sure that the sealing washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. After the spark plug is seated, tighten with a spark plug wrench to compress the washer. If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress the washer.
  • Página 44: Spark Arrester Screen

    11/04/26 16:14:35 32Z30600_044 SPARK ARRESTER CLEANING If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding. Remove the two 5 mm screws, and remove the spark arrester. 5 mm SCREWS SPARK ARRESTER Use a brush to remove carbon deposits from the spark arrester screen.
  • Página 45: Transporting/Storage

    11/04/26 16:14:46 32Z30600_045 TRANSPORTING/STORAGE Transporting To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position, with the engine switch OFF. The fuel valve lever should be turned OFF. When transporting the generator: Do not overfill the tank.
  • Página 46 11/04/26 16:14:50 32Z30600_046 Take care not to drop or strike the generator when transporting. Do not place heavy objects on the generator. When transporting the generator by loading it on to a vehicle, secure to the generator frame as shown.
  • Página 47 11/04/26 16:14:58 32Z30600_047 Storage Place a suitable gasoline container below the carburetor, and use a funnel to avoid spilling fuel. Remove the drain bolt and sealing washer and drain the gasoline from the carburetor. Gasoline is extremely flammable and is explosive under certain conditions.
  • Página 48 11/04/26 16:15:06 32Z30600_048 Remove the sediment cup (see page ), and then turn the fuel valve lever to the ON position. Allow the gasoline to drain completely, and then install the sediment cup (see page FUEL VALVE LEVER Change the engine oil (refer to page Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder.
  • Página 49: Troubleshooting

    Turn off the engine switch and remove the take the drain bolt (see page generator to an Turn the fuel valve lever to ON. Fuel authorized should flow from the drain when the fuel Honda dealer. valve lever is turned on.
  • Página 50 Reset the AC protector ON? circuit protector (see page Check the electrical Take the generator NO DEFECTS appliance or to an authorized equipment for any Honda dealer. defects. Replace the electrical appliance or equipment. DEFECTS Take the electrical appliance or...
  • Página 51: Specifications

    11/04/26 16:15:46 32Z30600_051 SPECIFICATIONS Dimensions and Weight Model EG3600CL EG4500CL Type BT, FT, GT, GWT, ITT Description code EBGC EBEC Length 681 mm (26.8 in) Width 530 mm (20.9 in) Height 571 mm (22.5 in) Dry mass [weight] 68.0 kg (149.9 lbs) 79.5 kg (175.3 lbs)
  • Página 52 11/04/26 16:15:59 32Z30600_052 Dimensions and Weight Model EG5500CL Type BT, FT, GT, GWT, ITT Description code EBBC Length 681 mm (26.8 in) Width 530 mm (20.9 in) Height 571 mm (22.5 in) Dry mass [weight] 82.5 kg (181.9 lbs) Engine Model GX390 Engine Type...
  • Página 53 11/04/26 16:16:11 32Z30600_053 Noise Model EG3600CL EG4500CL EG5500CL Type BT, FT, GT, GWT, ITT Sound pressure level at 79 dB (A) 81 dB (A) the workstation (2006/42/EC) Microphone point CONTROL PANEL Center 1.60 m 1.0 m Uncertainty 2 dB (A)
  • Página 54: Installation Of Kit Parts

    11/04/26 16:16:17 32Z30600_054 INSTALLATION OF KIT PARTS OPTIONAL KIT PARTS Handle Installation (Two wheel type) Install the right and left handles on the generator upper frame using the handle brackets and four flange bolts. TORQUE: 24 29 N·m (2.4 3.0 kgf·m , 17 22 lbf·ft) −...
  • Página 55 11/04/26 16:16:27 32Z30600_055 Two Wheel Kit Installation Install the two wheels on the axle shaft using the plain washers and split pins. Install the axle assembly on the generator using four 8 × 16 mm flange bolts and 8 mm flange nuts. Install the two stands on the under frame using four 8 ×...
  • Página 56 11/04/26 16:16:36 32Z30600_056 Four Wheel Kit Installation Install the lock plate and four wheels on the wheel shaft using the plain washers and split pins. Install the front wheel shaft on the front side nearest the engine. Install the wheel shaft assembly on the generator using eight 8 ×...
  • Página 57: Wiring Diagram

    EG3600CL (BT type): 1·EG4500CL, EG5500CL (BT type): 2 * * ..W 1 − EG3600CL (GT, GWT types): 1·EG4500CL, EG5500CL (GT, GWT * types): 2·EG3600CL (FT type): 3·EG4500CL, EG5500CL (FT type): 4 * * * ·EG3600CL (ITT type): 5·EG4500CL, EG5500CL (ITT type): 6 * * ..
  • Página 58: Switch Connections

    11/04/26 16:16:56 32Z30600_058 SWITCH CONNECTIONS ENGINE SWITCH DC 12 V RECEPTACLE Type Shape Plug GROUND PIN GT, GWT, GROUND PIN GROUND PIN BT, FT, ITT illustration not available...
  • Página 59 11/04/26 16:16:58 32Z30600_059...
  • Página 60 11/04/26 16:17:00 32Z30600_060...
  • Página 61: Wiring Diagram

    11/04/26 16:17:05 32Z30600_061 WIRING DIAGRAM SCHÉMA DE CABLAGE SCHALTPLAN DIAGRAMA DE CONEXIONES...
  • Página 62 11/04/26 16:17:18 32Z30600_062 −...
  • Página 63 11/04/26 16:17:31 32Z30600_063 −...
  • Página 64 11/04/26 16:17:33 32Z30600_064...
  • Página 65: Major Honda Distributor Addresses

    Weitere Informationen erhalten Sie gerne vom Honda- Kundeninformationszentrum unter der folgenden Adresse oder Telefonnummer: DIRECCIONES DE LOS PRINCIPLES CONCESIONARIOS Honda Para obtener más información, póngase en contacto con el Centro de información para clientes Honda en la dirección o número de teléfono siguientes:...
  • Página 66 11/04/26 16:17:57 32Z30600_066 AUSTRIA CROATIA FINLAND Honda Motor Europe (North) Hongoldonia d.o.o. OY Brandt AB. Hondastraße 1 Jelkovecka Cesta 5 Tuupakantie 7B 2351 Wiener Neudorf 10360 Sesvete − Zagreb 01740 Vantaa Tel. : + 43 (0)2236 690 0 Tel. : +...
  • Página 67 @ @ info hondakisgepek.hu honda.produtos honda-eu. ICELAND NETHERLANDS REPUBLIC OF BELARUS Bernhard ehf. Honda Motor Europe (North) Vatnagardar 24-26 Afd. Power Equipment- Scanlink Ltd. 104 Reykdjavik Capronilaan 1 Kozlova Drive, 9 Tel. : + 354 520 1100 1119 NN Schiphol-Rijk...
  • Página 68 CR honda.ua ventas aucasa.com @ taller aucasa.com @ SLOVAKIA REPUBLIC SWEDEN UNITED KINGDOM Honda Slovakia, spol. s r.o. Honda Nordic AB Honda (UK) Power Equipment Prievozská 6 821 09 Bratislava Box 50583 - Västkustvägen 17 470 London Road Tel. : +...
  • Página 69: Ec Declaration Of Conformity

    Neder Authorized representative Authorized representative EG-verk EG-ve 1. Onder 1. Ond Honda Motor Europe Ltd. Aalst Office Honda Motor Europe Ltd. Aalst Office de gema de gem dat het h dat he Wijngaardveld 1 (Noord V), Wijngaardveld 1 (Noord V),...
  • Página 70 Français. (French) Français. (French) Italiano (Italian) Italiano (Italian) Deutsch (German) Deutsch (German) Déclaration CE de Conformité Déclaration CE de Conformité Dichiarazione CE di Conformità Dichiarazione CE di Conformità EG-Konformitätserklärung EG-Konformitätserklärung es that res that 1. Le sous signé, Piet Renneboog, de la part du 1.
  • Página 71 Português ( Portuguese ) Português ( Portuguese ) Polski ( Polish ) Polski ( Polish ) Suomi / Suomen kieli (Finnish) Suomi / Suomen kieli (Finnish) Lietuvių ka Lietuv Declaração CE de Conformidade Declaração CE de Conformidade Deklaracja zgodności WE Deklaracja zgodności WE EB atitikties EY-VAATIMUSTENMUKAISUUSVAKUUTUS...
  • Página 72 Lietuvių kalba (Lithuanian) Lietuvių kalba (Lithuanian) Български (Bulgarian) Български (Bulgarian) Norsk (Norwegian) Norsk (Norwegian) EB atitikties deklaracija ЕО декларация за съответствие EF- Samsvarserklæring EB atitikties deklaracija ЕО декларация за съответствие EF- Samsvarserklæring 1. Įgaliotojo atstovo vardu pasirašęs Piet 1.Undertegnede Piet Renneboog på vegne av ettu 1.

Este manual también es adecuado para:

Eg4500clEg5500cl

Tabla de contenido