Cycle Segment Charts
Display
PrE
00 or 02 to 30
HFIL, CFIL, bFIL,
or AFIL
n
LO,
ed, or HI
SUP0–SUP6
00°F, 75°F–200°F
00°C, 25°C–93°C
SPIn (flashed for one second)
n
tI
E (flashed for one second)
00 or 30 to 240
F232061
Segment 1 (Prewash)
Use Up or Down key to change. Press Start key to enter or advance.
Select segment time: 02 to 30 minutes (00 to skip segment).
Select "HFIL" (hot fill), "CFIL" (cold fill), "bFIL" (warm fill), or "AFIL"
(auxiliary fill).
Select fill level: "LO" (low), "
Select supply 0–6 (0 for no supply).
Select temperature: 75 to 200° F or 25 to 93° C (00 for no heat).
Select time for spin: 30 to 240 seconds (00 for no spin)
Programming
Instructions
n
ed" (medium), or "HI" (high) water level.
27