Risk of electric shock. Can shock, burn or kill.
Risk of issues to be aware of:
• Drive's internal components retain high voltage for up to 5
minutes after input power is disconnected
See Owner's Manual for more illustrations and de-
NOTICE:
tailed information.
Tank air pressure must be at 70% of the system's set-point.
Pump Start-Up
The discharge pressure of the pump equals the pressure
produced by the pump plus the pressure on the suction side
of the pump.
Make sure that the suction and discharge shutoff valves are
both open.
When the system is connected to the power supply it
initializes. The green LED will be ON and the Pentair logo
shows up on the display (Figure a). As this initialization ends,
the pump stops and the display shows STOP(Figure b).
(a)
(b)
LINE
RUN
FAULT
MODE
SET
ESC
If you need to change the set-point, wait for the initialization
to complete and then push the up
Hold down the button until the desired set-point is displayed.
1.
Start the pump by pressing on the ON/OFF
LINE
RUN
FAULT
MODE
SET
ESC
2. The pump should start when the pressure drops below
the set-point and pressure should return to the set-point and
stay there. Do not run the pump with the discharge shut-off
valve closed! If the system goes to PROTECTION mode, refer
to the "Quick Troubleshooting Guide".
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.PUMPS.COM
PH: 888-237-5353 ORDERS FAX: 800-321-8793
© 2017 Pentair plc. All Rights Reserved.
LINE
STOP
STOP
RUN
FAULT
MODE
SET
ESC
or down
button.
button.
The pump starts and
reaches the pressure
level set at the factory
(default is 60PSI). The
RUN/FAULT LED will be
ON and showing green. If
the system pressure is
equal to or higher than
the factory pressure
setting, the pump will be
in stand-by mode (green
LED ON), ready to start if
the pressure decreases.
Intelliboost
Programming
1. Language setting:
To change the language, press the SET button
fr
en
LINE
60 PSI
es
PRESSURE
RUN
FAULT
MODE
SET
ESC
2. Display setting:
Press MODE to change the display configuration and choose
between GRAPHIC (a) and TEXT (b) modes.
LINE
a)
RUN
FAULT
MODE
LINE
RUN
MODE
3. Pressure level setting (set-point):
To increase or decrease the set-point, press the up
down
buttons.
(a)
+
LINE
4
SET
PSI
RUN
FAULT
MODE
SET
ESC
QUICK START GUIDE
R Series
®
PRESSION
PRESSURE
PRESIÓN
60 PSI
b)
MODE
SET
ESC
(b)
-
LINE
2
PSI
SET
RUN
FAULT
MODE
SET
ESC
253PB510 (01/17/17)
or