Descargar Imprimir esta página

Cooper Lighting HALO TGS3S401MSRB Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

• Do not install more than one motion activated floodlight on one wall switch.
ADJUSTING THE LUMEN OUTPUT
• This product features selectable lumen output. Choose between three preset
lumen outputs on the dial of the base housing before, during, or after installation
(Fig. 2):
• These settings are designated by the abbreviations located on the center dial on
the base housing (Fig. 2):
• High = 3000lm (Triple Head and Single Head), 2500lm (Twin Head Fixtures)
• Med = 2500lm (Triple Head), 2200lm (Single Head), 2000lm (Twin Head)
• Low = 2000lm (Triple Head), 1500lm (Single Head and Twin Head)
• Use a flathead to rotate the dial so the arrow points toward the desired setting.
• DO NOT USE a power tool or over-rotate the dial
MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
NOTE: Fixture can be wall or eave mounted (Fig. 3).
NOTE: Mounting bracket mounts to recessed mounted
standard junction boxes (Fig. 4). Junction box must be
at least 1-1/2 inch in depth for proper installation for
recessed mount application. For surface mount junction
box installation, refer to installation instructions included
with the adapter plate kit (E).
1. Line up the slots on the mounting bracket (B) with
the holes on your junction box. Using either (2)
#6 screws or (2) #8 screws (D) (depending on
size of the holes in your junction box), attach the
mounting bracket (B) to your junction box (Fig. 5).
Be sure the mounting bracket is installed with the
funnel for the central mounting screw going into
the junction box.
2. Make the electrical connection between the
ground wire on the mounting bracket and the
ground wire inside of the junction box.
3. Disconnect the male connector in the back of the
fixture. Insert the junction box wires to the male
connector while ensuring the hot wire (black)
and neutral wire (white) are connected to the cor-
responding black and white connections on the
male connector. (Fig. 6)
3/8"
Note: Be sure these are solid wires and stripped
3/8".
4. Plug the male connector into the female connec-
tor through the gasket (C). Rotate the connector
so it is recessed within the back surface of the
fixture. (Figs. 7 & 8)
5. Attach fixture (A) to the mounting bracket (B)
using the central mounting screw that is already
installed in the fixture. Be sure no loose wires re-
main sticking out from underneath the coverplate.
Insert the decorative screw cover cap (F) into
the screw hole on the coverplate for a finished
appearance (Fig. 9).
6. Adjust light fixture to desired position by loosen-
ing the thumbscrew on the upper arm. Move the
head to aim and retighten the thumbscrew.
7. Apply silicone caulk around the edges of the
canopy to provide a watertight seal from rain and
moisture.
8. Turn on power at main fuse/breaker box.
7
8
FIG.7
FIG.7
2
FLOOD
FIG.1
3
Wall Mount
Wall mount
Eave Mount
4
Eave mount
FIG.3
1-1/2 in.
Round
FIG.3
5
B
D
D
FIG.4
6
A
FIG.6
9
B
C
A
Screw Cover Cap
F
FIG.8
FIG.9
OPERATING YOUR FIXTURE
1. Rotate duration knob on bottom of the sensor to"TEST".
2. Turn the arrow on the sensitivity knob to a middle point between "Max" and "Min."
3. Turn on the power to fixture. Allow fixture to warm up approximately 40 seconds
before testing. (Lights may not come on during warm-up period.)
4. Aim sensor head toward desired detection area. The motion sensor should be aimed
down from the horizontal plane by a 5°–15° angle.
5. Walk across the detection zone at the farthest distance you wish your motion sensor
to detect motion.
6. Adjust sensor head angle until you get desired results. Lights will turn off 2-4 seconds
after all motion stops.
NOTE: For maximum range performance, allow fixture to operate in any mode (with
power to the unit) for at least 48 hours.
7. To set the ON time, rotate duration knob arrow to point to the desired time setting
within the range (up to 12 minutes). This will be the duration the light stays on at full
output after motion is detected.
8. Select the Standby Dim Level of your fixture by adjusting the Dim Knob on the bottom
of the motion sensor. If the knob is set to 0%, the fixture will turn off when no motion
is detected, and the ON time selected in step 7 times out. If the knob is set to 100%
the fixture will not dim when no motion is detected. If the knob is set to a point
between 0% and 100% the fixture will dim to the set level when no motion is detected,
and the ON time selected in step 7 times out.
Wall mount
SELECTING YOUR DESIRED FEATURE
Mode of Operation
Auto Setting (motion
Eave mount
activated) Lights should
FIG.3
turn ON with motion only
at night and should turn
OFF according to the dial
setting.
Dusk to Dawn Setting
1-1/2 in.
(activated only at night)
Lights should turn ON for
6 hours at dusk and then
reset to the Auto Setting.
Octagonal
Test Setting
Lights should turn ON with
motion both day and night.
Junction box
Lights should turn OFF
after 4 seconds.
Return to Auto Setting
(motion activated)
From any of the above
settings.
B
Central Mounting
Screw
2
Duration Adjustment Knob How to Set Power Switch
Knob arrow points to
Turn the power to the
desired time setting
fixture ON.
within the range.
Knob arrow points to
Turn the power OFF and
desired time setting
ON twice within 3 seconds.
within the range.
TEST
Turn the power to the
fixture ON.
Knob arrow points to
Turn the power OFF for at
desired time setting
least 40 seconds and then
within the range.
back ON.

Publicidad

loading

Este manual también es adecuado para:

Halo tgs3s401msrwHalo tgs2s402mrrbHalo tgs2s402mrrwHalo tgs2s402msrbHalo tgs2s402msrwHalo tgs3s403mrrb ... Mostrar todo