6) Disposal
As for the installation, the disposal of the product at the end of its
effective life, must be performed by qualified personnel.
This product is made of various types of material, some of which can
be recycled while others must be disposed of. Enquire about the
recycling or disposal systems available for this product category in
compliance with regulations locally in force.
Warning: some parts of the product may contain polluting or haz-
ardous substances that, if incorrectly disposed of, could have a
damaging effect on the environment or on the health of individuals.
7) What to do if...
a short troubleshooting guide!
The 2 beeps are not heard after the motor has been
switched on and the Step-by-Step does not command any
operations.
Check that the motor is supplied with the foreseen mains power
supply. If the power supply is correct there could be a serious fault
and the motor needs to be replaced.
6 beeps are heard after a remote control command is sent
and the manoeuvre does not start.
The remote control is not synchronised therefore the transmitter
needs to be memorised again.
10 beeps are heard after a command and the manoeuvre
starts.
The self-diagnosis of the parameters in the memory has detected a
fault (positions, TTBUS address, wind and sun level, movement
direction incorrect). Check and if necessary repeat the programming.
The motor does not move after a command is given.
• The thermal cutout may have tripped, therefore wait for the motor
to cool
• It may be that the set threshold has been exceeded if a wind sen-
sor has been installed
• If a "FT210S" photocell and/or resistive edge are connected, and
have been activated, the movement command is not accepted
• Otherwise, try turning the motor on and off. If 2 beeps are not
heard it may be that the motor has a serious fault and therefore
needs replacing.
The motor stops before reaching the foreseen opening
position (pos. "0", pos. "I") and attempts to start again
twice.
This is normal if the programming of the "0" and "1" positions has
been performed in the SEMI-AUTOMATIC mode: in case of overload
during the opening manoeuvre, the motor is turned off for approxi-
mately 1 second and then attempts to complete the manoeuvre.
Check if there are any obstacles preventing the manoeuvre.
11
As indicated by the symbol in figure, this
product must not be disposed of in house-
hold waste. Perform "separated collection"
for disposal in compliance with regulations
locally in force, or return the product to the
manufacturer when purchasing a replace-
ment.
Heavy fines may be imposed by local laws for the illegal disposal of
this product.
The motor stops before reaching the foreseen opening or
closing positions (pos. "0", pos. "I", pos. "1").
This is normal: in case of overload the motor is turned off. Check if
there are any obstacles preventing the manoeuvre.
The motor moves only in the "hold-to-run" mode.
If the "0" and "1" have not been programmed the opening and clos-
ing manoeuvre of the motor occur in hold-to-run only. Program the
"0" and "1" positions.
The "0" and "1" positions have been programmed but the
closing manoeuvre has a hold-to-run movement.
The self-diagnosis of the parameters in the memory has detected a
fault in the motor's position. Give the awning an up command and
wait for it to reach the "0" position.

Publicidad