ESPECIFICACIONES DE INSTALACIÓN (continuación)
Drawing Title: LES-B-127-XXXX-03
INSTALACIÓN DE LA PLACA DE ABRAZADERA (TÍPICA)
**CLAMP PLATE INSTALLATION FOR PINS ≤ ⌀0.25 [7.0]; PINS >⌀0.25 [7.0] USE HEAD-TO-HEAD INSTALLATION ON SHEET LES-B-127-XXXX-04 & -05.**
B
C
NOTES:
1.
CLAMP PLATE APPLICATIONS REQUIRE GUIDED EJECTION
2.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN
0.030" [0.76] OR 10% OF EJECTOR PIN DIA, WHICHEVER IS
SMALLER.
3.
ENCLOSED EJECTOR BOX SUGGESTED.
4.
DO NOT SCALE PRINT
5.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
6.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
7.
TOLERANCES UNLESS SPECIFIED:
XXX = ±0.003 [0.08]
XX = ±0.01 [0.3]
ANGLES = ±3 30°
Manual del Producto | Sensores Integrados Lynx ™ LES‑B‑127‑50/125/500/2000
Lynx™ Embedded Sensors (LES-B-127-XXXX) Installation—Clamp Plate Installation
B-Plate or Cavity Insert
Ejector Pin Installed with
Normal Slip-Fit Tolerances
H7/g6
Ejector Retainer Plate
Ejector Plate
Lead-In Chamfer
If Pin
If Pin > 0.12 [3.0], + 0.06 [1.5]
Ejector Pin Shoulder
and Transfer Pin
0.50 MIN [12 MIN]
H7/g6
Fit Must be 1/3 of Pin Length, Else
**Consider Head-to-Head Installation**
Clamp Plate
Cover Plate 32HRC
REFER TO TABLE E
TABLE E
Sensor Model
MIN Plate Thickness
LES-B-127-50
LES-B-127-125
LES-B-127-500
LES-B-127-2000
Refer to Product Manual for Cover Plate Alternatives
0.02 MIN
0.5 MIN
Per Side
45°
REFER TO TABLE D
< 0.12 [3.0],
+ 0.04 [1.0]
DETAIL B
SCALE 2.75 : 1
Equal
F
0.001 [0.03] F
0.001 [0.03]
+
0.005
0.510
-
0.000
0.2 [5]
[13.0 0.1]
0.2 [5]
0.25 [6]
0.25 [6]
Standard Fit
Part Thickness < 0.05 [1.5], 1/5 of Thickness
Part Thickness > 0.05 [1.5], 0.01 [0.3]
Ejector Pin ⌀
0.04–0.08 [1.0–2.0]
0.10–0.20 [2.5–5.0]
0.24–0.40 [6.0–10.0]
0.01 MIN
0.3 MIN
Counterbore in Ejector Plate
Transfer Pin Flush with Ejector Plate
30° Chamfer
Depth Equal to Pin
45°
REFER TO
TABLE D
RJG, Inc.
DETAIL C
3111 Park Drive
SCALE 2.75 : 1
231-947-3111
www.rjginc.com
TABLE D
Chamfer Length
0.01 [0.3]
0.02 [0.4]
0.025 [0.6]
0.01 MIN
0.3 MIN
+
0.002
0.374
-
0.001
[9.49 0.04]
Description: LES-B-127-XXXX
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M. Groleau
Date: 03.03.2021
11