Output; Supply Voltage; Sensor Supply Voltage; Climatic Conditions - Kübler CODIX 923 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Switching level with AC supply:
HTL level
Low:
High:
5V level
Low:
High:
Switching level with DC supply:
HTL level
Low:
High:
5V level
Low:
High:
Minimum pulse length of the Reset input:
Minimum pulse length of the Control inputs:10 ms
10.6

Output

Relay with changeover contact
Switching voltage
max. 250 VAC/ 150 VDC
Switching current
max. 3 A AC/DC
min. 30 mA DC
Switching capacity
max. 750 VA / 90 W
Mechanical service life (switching cycles) 20x10
N° of switching cycles at 3 A/ 250 V AC
N° of switching cycles at 3 A/ 30 V DC
10.7

Supply voltage

AC supply:
90 ... 260 V AC / max. 8 VA
50/ 60 Hz
ext. fuse protection: T 0.1 A
DC supply:
10 ... 30 V DC/ max. 1.5 W
reverse polarity protection
ext. fuse protection T 0.2 A
10.8

Sensor supply voltage

AC supply:
24 V DC 15%, 80 mA
DC supply:
max. 80 mA, external voltage
supply is connected through
10.9

Climatic Conditions

Operating temperature: -20°C .. +65°C
Storage temperature:
Relative humidity: RH. 93% at +40°C,
Altitude:

10.10 EMC

Noise immunity:
EN61000-6-2
with shielded signal and
control cables
Noise emission:
EN55011 Class B

10.11 Device safety

Design to:
EN61010 Part 1
Protection Class:
Class 2
Application area:
Soiling Level 2

10.12 Mechanical Data

Housing:
Panel-mount housing
Page 16
0 ... 4 VDC
12 ... 30 VDC
0 ... 2VDC
3,5 ... 30 VDC
0 ... 0,2 x UB
0,6 x UB ... 30 VDC
0 ... 2 VDC
3,5 ... 30 VDC
1 ms
5x10
5x10
-25°C .. +75°C
non-condensing
to 2000 m
Dimensions:
Panel cut-out:
Installation depth:
Weight:
Protection:
Housing material:
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
(EN60068-2-27):
(EN60068-2-29):
Shock resistance
(EN60068-2-27):
Cleaning:

10.13 Connections

Supply voltage and output:
6
Plug-in screw terminal, 7-pin, RM5.08
4
Core cross section, max. 2.5 mm²
4
Signal and control inputs:
Plug-in screw terminal, 8-pin, RM 3.81
Core cross-section, max. 1.5 mm²

11 Scope of Delivery

Delivery includes:
Preset counter
Mounting clip
Instruction manual

12 Ordering codes

6.923.X10X.XX0
to DIN 43 700, RAL 7021
48 x 48 x 91 mm
+0,6
+0,6
45
x 45
mm
ca. 107 mm incl. terminals
ca. 125 g
IP 65 (front)
Polycarbonate UL94 V-2
3 times in each direction
10G / 6 ms/ XYZ
2000 times in each direction
100G / XYZ
3 times in each direction
The front of the unit should
only be cleaned using a soft
damp (water!) cloth.
Input trigger levels
0 = Standard (HTL)
A = 5V
Supply voltage
0 = 90 .. 260 VAC
3 = 10 .. 30 VDC
LCD version
0 = no backlighting
1 = green backlighting
2 = LED Look
3 = Multicolour
Relay output
Front
0 = Kübler version
A = Neutral version
www.kuebler.com