Ecoflam Multicalor 45 Manual De Instrucciones página 14

Quemadores mixtos gas/ gasoleo
Ocultar thumbs Ver también para Multicalor 45:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
420010239601 M ul t i c al or 45 ÷ 140 PR/ PR
EN
MANUAL RELEASE
SWITCH
1
AD J U STI N G TH E M AXI M U M CAPACI TY O F TH E BU RN ER
Position the selector, situated on the control panel, on position maximum power and proceed as follows:
Adj us t i ng t he m axi m um gas f l ow r at e: - proceed as stated in the regulating the solenoid valves until you achieve the
correct gas flow, as established by analyzing the combustion process. Eventually adjust the gas flow rate using a suitable
allen wrench, alter the position of the cam(3) guide blade; if you screw it down, the flow rate is reduced; if you unscrew
it, the flow rate increases.
Adj us t i ng t he m axi m um ai r f l ow r at e:Eventually adjust this position acting on the screw "1 ", after loosening nut " 2
".
"2"
Tighten the nut
AD J U STI N G TH E M I N I M U M CAPACI TY O F TH E BU RN ER
Position the selector, situated on the control panel, on position minimum power and proceed as follows:
Adj us t i ng t he m i ni m um gas f l ow r at e: using a suitable Allen wrench, alter the position of the cam(3) guide blade; if
you screw it down, the flow rate is reduced; if you unscrew it, the flow rate increases.
Adj us t i ng t he m i ni m um ai r f l ow r at e: adjust on limit switch for air damper "Low Flame" position adjustment.
AD J U STI N G TH E I N TERM ED I ATE BU RN ER CAPACI TI ES
Using the selector, start the servomotor (closing or opening) and position on 0 to stop the stroke; the adjustment is
made as outlined below. Repeat the operation for the other cam points.
Adj us t i ng t he i nt er m edi at e gas f l ow r at es :using a suitable Allen wrench, alter the position of the cam(3) guide blade; if
you screw it down, the flow rate is reduced; if you unscrew it, the flow rate increases.
AD J U STEM EN T O F TH E CO M BU STI O N AI R
LAN D I S & STAEFA SQ N 30/ 31 251A2700 AI R D AM PER M O TO R
Remove cover to gain access to the adjusting cams.The cams are to be adjusted
through the suitable key provided for. Description:
I - Limit switch for air damper "High Flame" position adjustment
I I - Limit switch for the air damper position at burner's shut down
I I I - Limit switch for air damper "Low Flame" position adjustment
V - Limit switch "NOT USED".
2
.
in place once again
(Max. power)
(Min. power)
AI R AD J U STM EN T
14
SELECTOR
AUTO
3
0
0 = operating elements locked
in an intermediate position
= operation on maximum capacity
= operation on minimum capacity
AUTO = automatic operation

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multicalor 70Multicalor 100Multicalor 140

Tabla de contenido