Safety and Installation Instructions 
(English ‐ IEC version) 
 
 
This document includes references to SunPower E‐series (SPR‐
Eyy‐zzz), X‐series (SPR‐Xyy‐zzz), P‐Series (SPR‐Pyy‐zzz, SPR‐P3‐
 
zzz), SPR‐MAX2‐zzz, SPR‐MAX3‐zzz PV Modules. 
 
Do not mix E, X, MAX2, MAX3, P Series and P3 in one System. 
 
All module series does not require functional grounding and are 
compatible with transformer‐less inverters (ref. section 4.1) 
 
1.0
Introduction  
This  manual  provides  safety  and  installation  instructions  for  IEC 
certified SunPower photovoltaic modules carrying the TUV logo on the 
product label (Figure 1).  
 
Important!  Please read this instruction sheet in its entirety 
before  installing,  wiring,  or  using  this  product  in  any  way. 
Failure to comply with these instructions will invalidate the 
SunPower Limited Warranty for PV Modules. 
 
1.1 Disclaimer of Liability 
The  installation  techniques,  handling  and  use  of  this  product  are 
beyond  company  control.  Therefore,  SunPower  does  not  assume 
responsibility  for  loss,  damage  or  expense  resulting  from  improper 
installation, handling or use. 
 
1.2  Conformity  to  International  Electrotechnical  Commission  (IEC) 
standards 
This  product  meets  or  exceeds  the  requirements  set  forth  by  IEC 
61215 Edition 2‐2005 and Edition 3‐2016 for PV Modules, as well as 
IEC  61730  Edition  1  and  2  series  for  Class  II  applications.  The  IEC 
Standard  covers  flat‐plate  PV  modules  intended  for  installation  on 
buildings and those intended to be freestanding. This product is not 
intended for use where artificially concentrated sunlight is applied to 
the module. 
This  manual  shall  be  used  in  combination  with  industry  recognized 
best practices. Modules should be installed by certified professionals 
only. 
 
1.3 Limited Warranty 
Module  limited  warranties  are  described  in  the  SunPower  warranty 
document  obtainable  at  www.sunpower.com.  Please  read  this 
document for more information. 
Warranties do not apply to any of the following; 
PV modules which in SunPower's absolute judgment have been 
subjected  to:  misuse,  abuse,  neglect  or  accident;  alteration, 
improper installation, application or removal  (including but not 
limited to installation, application or  removal by any party other 
than  a  qualified  personnel;  non‐observance  of  SunPower's 
installation,  users  and/or  maintenance  instructions;  repair  or 
modifications  by  someone  other  than  an  approved  service 
technician; power failure surges, lightning, flood, fire, accidental 
breakage or other events outside SunPower's control.   
2.0
Safety Precautions 
Before installing this device, read all safety instructions in this manual. 
 
©November 2019 SunPower Corporation. All rights reserved. Specifications included in this manual are subject to change without notice. 
 
Figure 1 
Safety and Installation Instructions ‐ Document 001‐15497 Rev S
Danger! Module interconnects pass direct current (DC) and are 
sources of voltage when the module is under load and when it is 
exposed  to  light.  Direct  current  can  arc  across  gaps  and  may 
cause injury or death if improper connection or disconnection is 
made, or if contact is made with module components that are 
damaged. Do not connect or disconnect modules when current 
from the modules or an external source is present. 
 Cover all modules in the PV array with an opaque cloth or material 
before making or breaking electrical connections. 
 Do not disconnect any modules when its inverter is feeding in to 
the grid. Switch off the inverter before disconnecting, reinstalling 
or making any action with the modules. 
 For  connectors,  which  are  accessible  to  untrained  people,  it  is 
imperative  to  use  the  locking  connectors  and  safety  clips,  if 
applicable,  in  order  to  defend  against  untrained  personnel 
disconnecting the modules once they have been installed. 
 All  installations  must  be  performed  in  compliance  with  all 
applicable regional and local codes. 
 There  are  no  user  serviceable  parts  within  the  module.  Do  not 
attempt to repair any part of the module. 
 Installation should be performed only by qualified personnel.  
 Remove  all  metallic  jewelry  prior  to  installing  this  product  to 
reduce the chance of accidental exposure to live circuits. 
 Use insulated tools to reduce your risk of electric shock. 
 Do not stand on, walk, drop, and scratch or allow objects to fall on 
the glass surface of the modules. 
 Damaged modules (broken glass, torn back sheet, broken j‐boxes, 
 
broken  connectors,  etc)  can  be  electrical  hazards  as  well  as 
laceration  hazards.  Contact  with  damaged  module  surfaces  or 
module  frame  can  cause  electric  shock.  The  dealer  or  installers 
should remove the module from array and contact the supplier for 
disposal instructions. 
 Unconnected connectors must always be protected from pollution 
(e.g dust, humidity, foreign particles, etc), prior to installation. Do 
not leave unconnected (unprotected) connectors exposed to the 
environment. A clean assembly environment is therefore essential 
to avoid performance degradation. 
 Do not install or handle the modules when they are wet or during 
periods of high wind. 
 Do not block drain holes or allow water to pool in or near module 
frames 
 SunPower recommend to not mix 160mm cells and 166mm cells 
modules in a cosmetically sensitive application. 
 Contact your module supplier if maintenance is necessary. 
 Save these instructions! 
3.0
Electrical Characteristics 
The  module  electrical  ratings  are  measured  under  Standard  Test 
Conditions (STC) of 1 kW/m² irradiance with AM 1.5 spectrum and a 
cell temperature of 25 °C.  SunPower modules have specific electrical 
characteristics as shown on the datasheets. 
A  photovoltaic  module  may  produce  more  current  and/or  voltage 
than reported at STC. Sunny, cool weather and reflection from snow 
or water can increase current and power output. Therefore, the values 
of I
 and V
 marked on the module should be multiplied by a factor 
sc
oc
of  1.25  when  determining  component  voltage  ratings,  conductor 
ampacities, fuse sizes, and size of controls connected to PV output. An 
additional 1.25 multiplier may be required by certain local codes for 
sizing fuses and conductors. SunPower recommends the use of open‐
circuit voltage temperature coefficients listed on the datasheets when 
determining Maximum System Voltage. 