Maintenance and cleaning
All cleaning of all parts must be carried out with the stove com-
pletely
The stove does not need much maintenance if used with certified
quality pellet. The need for maintenance varies depending on the conditions of use
(switching on and off repeatedly) and depending on the performance required.
Parts
Brazier
Cleaning ash collection compartment
Cleaning ash tray
Cleaning the door and glass
Exchanger
Cleaning the interior heat exchanger /
smoke fan compartment
Cleaning complete exchanger
Clean "T" to exhaust
Flue
Door gasket ash
Internal parts
Flue pipe
Electromechanical components
◊ by the user
• by the authorised qualified technical assistance
Every 1200 hours of work the electronic board sends a warning signal and the
display will show " " S ERV IC E
stove by a CAT. The lack of such cleaning could result in failure of the stove and
poor combustion, thereby resulting in a lower yield.
cold
and
unplugged
Every 2-3
Everyday
◊
◊
S ERV IC E" " . This indicates the need for a thorough cleaning of the
to
avoid
Every
Every 15
days
week
days
◊
◊
◊
burns
and
thermal
Every 30
Every 60-
days
90 days
•
•
•
shock.
Every year /
1200-1400 h
•
•
•
•
•
21