Installation Procedures
If the elevation level of the indoor unit and drain pipe are
not affected, you can adjust the height of the indoor unit
through the corner pore on the trim panel. Please keep
the unit horizontal in the process of adjustment, or else
water leakage is easy to occur.
• Please do not swing the louver blade by hand, or else the
blade mechanism would be damaged.
6) Connection of trim panel. Connect the black lead-out
terminal of the panel to the black lead-out terminal of the
indoor unit housing.
Indoor unit
Trim panel
7) When the installation of panel is complete, please fix the
four (4) angle trim panels.
• Hang and tighten the strap of the angle trim panel on the
shackle of the trim panel, as shown in the figure.
• Fix the angle trim panel on the trim panel.
Connecting terminal
Connecting to the panel side
Connecting terminal
Connecting to the indoor
unit side
8) Installing the air-inlet grille.
Install the air-inlet grille with the steps opposite to that for
removing.
For reference
The method for removing angle trim panels when the
installation of trim panel is complete:
a.Insert a straight screwdriver in the notch ① . Gently turn
the screwdriver downward, and slowly insert it in, and then
move it up and down to make the angle fall off.
b.Make the angle ② and ③ fall off in the same way.
c.Take off the angle trim panel by hand.
Angle trim panel
Requirements:
• The drainpipe of the indoor unit should be heat-insulated.
• Heat insulation should be treated for the connection
with the indoor unit. Improper heat insulation may cause
condensing.
• The drainpipe with the down gradient of over 1/100 can't
be in the S shape, or abnormal sound can be caused.
• The horizon length of the drainpipe should be kept with
20m. Under the condition of long pipes, supports can be
provided every 1.5~2m as to avoid unevenness.
• The central piping should be connected according the
following drawing.
• Take care not to apply external force on the connection of
the drainpipes.
1.5m~2m
heat
down gradient
insulating
over 1/100
material
as big as possible (about 10 CM)
down gradient
over 1/100