Resumen de contenidos para Airwell Flow logic III YDV Serie
Página 1
Installation Manual Flow logic III YDV Series R410A Multilingual Manual (English - - Deutsch - Italiano - Español - Português ) FRANÇAIS AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Página 2
Installation Manual Flow Logic III YDV Series R410A English Manual AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. 20.AW.YDV.08-24HP.R410A.IM.EN.FR.DE.IT.RU.SP.PO.05.18.Rev01...
Página 25
As R410A refrigerant is adopted for the unit, the following matters will be noted: (3) Charge additional refrigerant oil (4) Operating method of operating valve Opening/closing method 4. Seal in the charged additional refrigerant...
Página 26
AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 Important notes Separate the refrigerant system when exceeding values in the table As R410A refrigerant is adopted for the unit, the following matters will be noted:...
Página 27
Warning: 5. Heat insulation and dew prevention...
1. Wiring system diagram 2. Essentials in power supply wire connection (1) Wire removal method (2) Attentions during connection of power supply wires...
Página 30
three-phase power supply of 380V and 50/60Hz AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13...
Página 31
3. Essentials in signal wire connection...
Página 33
1. Setting of unit address Setting of outdoor unit address: Setting of centralization and communication addresses for indoor unit: … … … … … … … … … … … … … … … … … … 127#...
Página 42
4. Check the parameters for unit evaluation through dip switch panel of outdoor unit Parameter observation of indoor unit...
Página 43
Parameter observation of outdoor unit...
Página 47
It is used to view data in EE when SW9 is 12 and 13. … … … … … … … … … …… …… …… …… …… …… Data parameter information and control modes of the whole system are displayed when SW9 is 0...
Página 49
Dip switch setting condition of PCB board is displayed when SW9 is 15.
Página 50
Manual control for valve parts of outdoor unit:...
MANUALE DI INSTALLAZIONE Flow logic III YDV Series R410 A Italiano Manual AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 NOTA IMPORTANTE : Lea este manual atentamente antes de instalar o utilizar su nueva unidad de aire acondicionado. Asegúrese de guardar este manual para futuras referencias. 20.AW.YDV.08-24HP.R410A.IM.EN.FR.DE.IT.RU.SP.PO.05.18.Rev01...
Página 106
MANUEL D’INSTALLATION Flow logic III YDV Series R410A Manuel Français AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 IMPORTANT NOTE: Avant d 'installer ou de faire fonctionner le nouveau module de climatisation, lisez attentivement le manuel.Veuillez tenir ce manuel à jour pour les références futures. 20.AW.YDV.08-24HP.R410A.IM.EN.FR.DE.IT.RU.SP.PO.05.18.Rev01...
Página 156
votre distributeur pour une assistance technique.
Página 158
INSTALLATIONSANLEITUNG Flow logic III YDV Series R410A Deutsch M anual AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 WICHTIGE NOTIZ: Lesen Sie diese Anleitung sorgfältig durch, bevor Sie Ihr neues Klimagerät installieren oder betreiben. Stellen Sie sicher, dass Sie dieses Handbuch zur späteren Verwendung speichern.
Página 210
MANUAL DE INSTALACIÓN Flow logic III YDV Series R410A Español Manual AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 NOTA IMPORTANTE : Lea este manual atentamente antes de instalar o utilizar su nueva unidad de aire acondicionado. Asegúrese de guardar este manual para futuras referencias 20.AW.YDV.08-24HP.R410A.IM.EN.FR.DE.IT.RU.SP.PO.05.18.Rev01...
MANUAL DE INSTALAÇÃO Flow logic III YDV Series R410A Português Manual AWAU-YDV250-H13 AWAU-YDV280-H13 AWAU-YDV335-H13 AWAU-YDV400-H13 AWAU-YDV450-H13 AWAU-YDV504-H13 AWAU-YDV560-H13 AWAU-YDV615-H13 AWAU-YDV680-H13 IMPORTANT NOTE: Leia Atentamente este manual antes de instalar ou operar a SUA Nova unidade de ar condicionado.Certifique-se de GUARDAR este manual para referência futura. 20.AW.08-24HP.R410A.IM.EN.FR.DE.IT.RU.SP.PO.05.18.Rev01...
Página 284
(E) Após a confirmação através dos procedimentos de (A) a (D), se a pressão for baixa, existe um vazamento. Verifique a peça de solda, a parte alargada, etc. com a solução de teste de espuma, descubra o vazamento e repare-a. Teste a estanqueidade ao ar novamente após o reparo.
Página 313
Consult with the sales agency or manufacturer for details. ATTENTION : Le design et les données techniques sont donnés à titre indicatif et peuvent être modifiés sans préavis. AIRWELL RESIDENTIAL SAS 10,Rue du Fort de Saint Cyr, 78180 Montigny le Bretonneux- France www.airwell.com...