50 Amp Power Plug Connection; Circuit Protection; Low Oil Shutdown; Electric Start - Coleman Powermate Vertex Serie Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

50 AMP POWER PLUG CONNECTION

The above plug wiring diagrams depict a floating neutral
connection which is required in some localities. Check with your
electrician to determine proper grounding requirements. If a
grounded neutral connection is desired a jumper should be
installed between the white neutral connection and the green
ground connection in the plug.

CIRCUIT PROTECTION

AC FEATURES
The receptacles are protected by AC circuit breakers. If
the generator is overloaded or an external short circuit occurs,
a circuit breaker will trip. If this occurs, disconnect all electrical
loads and try to determine the cause of the problem before
attempting to use the generator again. If overloading causes
the circuit breaker to trip, reduce the load. NOTE: Continuous
tripping of the circuit breaker may cause damage to
generator or equipment. The circuit breaker may be reset by
pushing the button of the breaker or moving the arm on 2 pole
breakers to "ON" position if so equipped.

LOW OIL SHUTDOWN

All units are equipped with low oil shutdown. If the oil level
becomes lower than required, the generator set will
automatically shut off. This protects your generator set from
operating without proper lubrication.
If generator shuts off and the oil level is according to
specifications, check to see if generator is sitting at an angle
that forces oil to shift. Place on an even surface to correct this.
If engine fails to start, the oil level may not be sufficient to
deactivate low oil level switch. Be sure the sump is completely
full of oil.
NOTE: Maximum incline degree of the generator set
cannot be more then 25° from horizontal.
8
120-Volt Connection
control panel. All necessary wiring is provided. The battery is
not included - must be purchased separately. To ensure
reliable starting in the winter, Coleman recommends a 12V
battery with a minimum of 235 cold cranking amps.
models. Selected models also include a battery. To install the
battery and the battery pan in the battery panel, place the
battery belt laying on the panel and pan (as shown in the
diagram). Check to insure the battery pan is hooked over the
panel face and setting entirely on the lower shelf. After placing
the battery in the opening, connect the belt around the battery.
240-Volt Connection
terminals make battery hookup quite simple. Connect the black
lead hooked to the chassis to the negative (-) battery terminal
and the red lead from the starter solenoid to the positive (+)
battery terminal with the provided bolts, lock washers and nuts.
Place the red terminal cover securely over the positive battery
terminal. Insure that each battery cell contains the proper
amount of fluid.
connected to the positive (Red) battery lead. Battery charging
will occur when the engine is running.

ELECTRIC START

An "Off-On-Start" rotary key switch is provided on the
A battery compartment is provided on all electric start
Battery Panel
Battery Pan
Battery Belt
#8 AWG (American Wire Gauge) copper wire lead with ring
WARNING: Batteries contain sulfuric
acid (when filled) and may emit explosive
gasses. Always abide by safety warnings
provided with the battery.
-
Keep sparks, flame and cigarettes away.
-
Hydrogen gas is generated during
charging and discharging.
-
Always shield eyes, protect skin and
clothing when working near batteries.
The engine contains an internal battery charger which is
CAUTION: Do Not allow the positive (Red)
battery terminal to come in contact with any
metal parts of the unit. Engine or battery
damage may result.
English

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pm0558023Pm0555523Pc0555523.01Pm0557523.9Pc0557523.8

Tabla de contenido