Functioning Test; Adjusting Pause Time; Functions That Can Be Selected - Nice WIL Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
3.1) FUNCTIONING TESTS:
After the connections have been checked and verified (Chapter 2.3) the electrically controlled movement of the bar can be tested;
in this case we suggest you work in the manual mode with all the functions deactivated (all switches OFF); in all cases, in the
manual mode, by releasing the command key the motor stops immediately. If you use the Step-by-Step input command the first
movement (after turning on) should be an opening one.
By means of the command inputs, move the bar up to the opening point; about 20° from the stopping point the FCA limit switch
should trigger, activating the "slowing down" phase which makes the bar reach the set point at a slower speed. Now carry out a
closing phase until the closing point is reached; in this case too, the FCC limit switch should trigger, activating the slowing down
phase 20° before movement stops. Now test triggering of the safety devices: PHOTOCELL in opening has no effect while in the
closing phase it causes the bar to stop; PHOTOCELL 2 has no effect in the closing phase while in the opening phase it causes the
bar to stop. The devices connected to the STOP input act both in the opening and in the closing phases, causing the bar to stop.
The UNI 8612 standards state that the maximum thrust of an automatic device must not exceed 150 N (~13.5 kg); this is achieved
by adjusting the ammetric friction STOP_AMPERE. There is a trimmer on the card to establish the triggering threshold of this the
friction; is has to be adjusted so that it comes into action as soon as a light pressure is applied to the bar in the direction opposite
to the way it is moving.
To overcome the initial movement phase that always needs greater motor power, the STOP_AMPERE friction system is excluded
from the motor start up phase; to evaluate the effect of the adjustment on the trimmer, you ought to wait until the movement has
started and the bar has reached standard speed.
Keep in mind that, always for a question of safety, if the friction comes into play three consecutive times, movement is stopped
without any reversal.
If the automatic functioning mode is selected at the end of the opening manoeuvre, there is a "pause time" after which a closing
manoeuvre is automatically launched. Pause time is adjusted with the trimmer PAUSE TIME. Pause time is also activated in the
semiautomatic functioning mode when, in the closing phase, the triggering of a safety device or the STOP_AMPERE friction,
causes a reversal in the opening manoeuvre.

3.2) ADJUSTING PAUSE TIME:

When the automatic closing function (see Chapter 5.1) is selected with the specific dip-switch, following an opening manoeuvre,
a timer is activated that controls the so-called "Pause Time"; when this time has elapsed a closing manoeuvre is automatically
activated. This time can be adjusted with the PAUSE TIME trimmer from 3 to 120 seconds.

4.1) FUNCTIONS that can be selected:

The FUNCTIONS dip-switch lets you select the various possible functioning modes and to enable the functions you want.
Switches 1-2: Off Off
On Off
Off On
On On
Switch 3:
On
Switch 4:
On
Switch 5:
On
Switch 6:
On
Switch 7:
On
Switch 8:
On
Switch 9
On
Switch 10
On
Of course, with each switch OFF the function described will not be activated.
16
= "Manual" movement (Man Present)
= "Semiautomatic" movement
= "Automatic" movement (Automatic Closing)
= "Automatic+Always Closes" movement
= Condominium functioning mode
= Cancels STOP in the Step-by-Step cycle
= Preflashing
= Flashing also in Pause
= Recloses straight after Photocell (only if on Automatic)
= Safety (Photocell) also in opening
= Bar open indicator becomes traffic light in the "one-way" mode
= Functioning in the "Traffic light in both directions" mode