4.2) DESCRIPTION OF THE FUNCTIONS:

Below is a brief description of the functions that can be selected; all the functions can be enabled or disabled without any limit
even if some combinations would have no sense and, therefore, not be carried out (for instance, function 6, Flashing also in
Pause, would not be carried out if movement is in the manual mode).
Switches 1-2:
When in the "Manual" functioning mode, movement will only be carried out while the command is being given (button pressed).
In the "Semiautomatic" mode just one command pulse is needed and the complete manoeuvre will be carried out until it is either
fully open or fully closed. In the "Automatic" functioning mode one command pulse will cause an opening manoeuvre to be
carried out followed by a pause and then a closing manoeuvre.
The "Always Closes" function works if, subsequent to a temporary power cut, the bar is still open; in this case, a closing
manoeuvre is started automatically preceded by 5 seconds of preflashing.
Switch 3:
In the Condominium functioning mode, once an opening manoeuvre has started, for instance with a Step-by-Step pulse, it cannot
be interrupted by any other command pulses until it has finished.
During a closing manoeuvre, a new command pulse will stop the bar and immediately reverse the direction, opening the bar.
Switch 4:
The Step-by-Step cycle is normally: OPEN-STOP-CLOSE-STOP; in this functioning mode the Step-by-Step cycle becomes:
OPEN-CLOSE-OPEN so the bar can never stop midway, but only when completely open or completely closed.
Switch 5:
The flashing light starts prior to each movement; after 5 seconds (2 seconds if on manual) movement starts.
Switch 6:
The flashing light is normally activated only during the opening and closing manoeuvres; with this function the flashing light
remains active also during the Pause Time to signal the "closing soon" condition.
Switch 7:
With this function the bar can be kept open only for the length of time needed for transit; in fact, it will close automatically always
5 seconds after the last object has passed by the "Photocell", irrespective of the programmed Pause Time.
Switch 8:
As a rule the safety "Photocell" only works in the closing cycle; if switch 8 is "ON" the triggering of the safety device will cause
the bar to stop even in the opening phase; if on Semiautomatic or Automatic, movement will start again, in opening, immediately
after the last object has passed by the Photocell.
Switch 9:
As an alternative to the Gate Open indicator, the output can be reprogrammed so that it performs the function of a "one-way"
traffic light; this means the output is off when the bar is closed or closing, and on when the bar is opening or is opened. In this
way, an indication can be fixed to the exit like: Green = Transit free.
Switch 10:
Several changes occur in the control unit when the "Traffic light in both directions" function is activated when Switch 10 is ON:
OPEN becomes STEP-BY-STEP 2, while the two outputs, Courtesy Light and Bar Open Indicator become a Green Light in both
directions. Due to the specific nature of this function we are giving a separate description.
Off Off
= "Manual" movement (Man Present)
On Off
= "Semiautomatic" movement
Off On
= "Automatic" movement (Automatic Closing)
On On
= "Automatic+Always Closes" movement
On
= Condominium function
On
= Cancels STOP in the Step-by-Step cycle
On
= Preflashing
On
= Flashing also in Pause
On
= Recloses straight after Photocell (only if on Automatic: Sw 2 = ON)
On
= Safety (Photocell) also in opening
On
= Bar open indicator becomes traffic light in the "one-way" mode
On
= Functioning in the "Traffic light in both directions" mode