Sydney 3 VCA-VCB-SELF-H125-H150
English
i
Article 3 section 3 of Directive CEE 97/23 (PED) does not apply to these cabinets.
The performance of these refrigerated cabinets was determined through tests conducted in
compliance with standard:
-
EN ISO 23953:2012 in environmental conditions corresponding to climatic class 3
(25 °C , 60% U.R.) see table:
Environmental climatic classes as per UNI EN ISO 23953
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapor in dry air is one of the main points that affect the performance and
power consumption of the cabinets
Declaration of
A copy of the conformity statement is annexed to the cabinet
conformity
If you lose the original copy of the Declaration of Conformity supplied with
the cabinet, download a copy by filling out the form available on the internet
addresses:
- for Italy: http://www.arneg.it/conformita/it
- overseas: http://www.arneg.it/conformita/en
4. Identification - Nameplate (Fig. 2)
:
On the display cases, the matriculation plate is on the back of the cabinet. For semi-verticals, the
plate is on the left, on the back:
1 Manufacturer's name and address
2 Name and length of the cabinet
3 Cabinet code number
4 Cabinet registration number
5 Power supply voltage
6 Power supply frequency
7 Max. absorbed current
8 Electrical power absorbed at steady state during refrigerating phase (fans + hot cables + lighting)
9 Electrical power absorbed at steady state during defrosting phase (heating elements + hot cables
+ fans + lighting)
10 Illuminating power (where applicable)
11 Useful display surface
12 Type of refrigerating fluid used in the appliance
13 Mass of refrigerating gas loaded in each individual appliance (only for cabinets with incorporated
motor)
14 Environmental climatic class and reference temperature
15 Class of protection against humidity
16 Manufacturing job number of the cabinet
17 Manufacturing order number of the cabinet
18 Manufacturing year of the cabinet
In case of technical service request, please communicate the following information for the
identification of the cabinet:
- products name
26
Dry bulb temp. Relative Humidity
°C
20
16
22
25
30
27
40
35
23,9
(Fig. 2 - 2);
Dew point
%
°C
50
9,3
80
12,6
65
15,2
60
16,7
55
20,0
70
21,1
40
23,9
75
30,0
55
14,3
Weight of water vapour in
dry air
g/kg
7,3
9,1
10,8
12,0
14,8
15,8
18,8
27,3
10,2
05060057 01 28/08/2015