Power unit
For an optimum lifetime the power unit must be
connected to the mains voltages as often as pos-
sible (e.g. every night). Charge the batteries 12
hours before use.
The batteries must be charged at least every 3rd
month - otherwise there might be damages due
to self-discharge. It is recommended to test the
battery function at least once every year.
Recharging the battery:
Plug the charging lead into the handset
•
Plug the charger into the electricity supply
•
and switch ON.
A yellow light on the charger will light up
Charge the batteries until the lamp on the
•
charger turns green
Caregiver
Do not leave children and youngsters alone
•
with the handset
Do not let children and youngsters play with
•
the handset
Do not leave the handset within reach of
•
children and youngsters it is important to
remove the transport plastic bag before us-
ing the handset. Cables need to be placed
in such a way that users or carers cannot
trip and injure themselves.
Product
The power unit does not have a safety stop
•
The system must not be sprayed directly
•
with a highpressure cleaner
Cleaning with a steam cleaner is not permit-
•
ted
Do only use the power unit within specified
•
working limits
It is recommended to check the handset
•
and cable for damage and holes caused by
violent handling at least once a year
Do not submerge the handset in water
•
Do not attempt to repair any part of the
•
power unit.
support.R82.org
ENGLISH
Technical Data
Battery - BA18
•
Capacity 1.3 Ah - 24V DC
•
Charging current is max. 500 mA
•
IPX6
•
Duty cycle: Max. 10% or 2 min. use then 18 min.
without use
The batteries have a maximum life of 4 years but this can
vary depending upon the conditions of use and charging
practices
Battery charger - CH01
•
Mains: 100 - 240VAC/50-60 Hz switch mode
•
Charging voltage: 27.6 VDC
•
Charging current: Max. 500 mA
Actuator - LA28
•
Input voltage: 24V
•
Noise level: ≤ 45 dB(A)
•
IPX1
Handset - HB 40
•
IPX1
Detachable parts
•
Handset - HB 40
•
Battery - BA 18
Applied part
•
Handset - HB 40
IP-Rating table
IPX0
No protection
IPX1
Protection against vertically falling
drops of water e.g. condensation
IPX2
Protection against direct sprays of
water up to 15° from the vertical
IPX3
Protected against direct sprays of
water up to 60° from the vertical
IPX4
Protection against water sprayed
from all directions - limited ingress
permitted
IPX5
Protected against low pressure jets
of water from all directions - limited
ingress
IPX6
Protected against temporary flood-
ing of water, e.g. for use on ship
decks - limited ingress permitted
IPX7
Protected against the effect of im-
mersion between 15 cm and 1 m
IPX8
Protects against long periods of im-
mersion under pressure
35
EN