Energetics CT 421pa Manual De Montaje página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
10
What does the POLAR® logo mean?
ENERGETICS products that carry this logo can be used with a uncoded
chest belt.
Problem
Solution
No resistance.
Manual controlled products:
1. Check if the plug of the resistance cable is correctly connected,
see chapter 'assembly'.
2. Check lower resistance cable which is connected to the break system.
Power magnetic (motor) controlled products:
1. Check if power cable is plugged-in.
2. Check the computer cable connection.
3. Check motor power connection.
4. Replace the motor.
Electromagnetic controlled products:
1. Check if power cable is plugged-in.
2. Check the computer cable connection.
3. Check the inner power cable to the break system and electronic board.
4. Replace the flywheel or electronic board.
1. Check the upper cable connections.
No speed signal.
2. Check if the speed sensor is in the right position.
3. Replace the speed sensor.
4. Replace the computer.
The upright post shakes.
1. Loose upright post screws.
2. Re-insert screws/washers and tighten screws equally.
1. Use the rear stabilizer height adjustment to level out any une-
The home fitness equipment shakes.
venness.
2. Move the equipment to a different place and check if the prob-
lem still persists.
The home fitness equipment creates
1. Check the fit of the stabilizer bolts.
abnormal noises.
2. Check the end caps.
3. Check whether the pedals are assembled correctly or not, see
chapter 'assembly'.
4. Check crank arms, turning discs, cross frames, axis, and bearings
(if applicable).
Error Code
Possible Cause
E1
1. Motor unable to get
Power magnetic (motor)
into
controlled products only
correct tension posi-
tion.
E2
1. EEPROM chip on control
board has a bad
connection.
2. The software stored in
the EEPROM chip on the
control board is
defective.
E4
1. No pulse signal input
when using body fat
calculator.
Things to check
Solution
Check if there is too much
1. Turn computer on and
tension on motor.
remove the motor
plug containing the
tension cable. Move
resistance level on
computer to maxi-
mum.
2. As soon as motor
reached maximum
position, re-insert the
plug containing the
tension cable.
3. Re-adjust tension,
if needed to ensure
maximum resistance.
4. Test all resistance
levels.
5. Replace motor or
computer if the prob-
lem persists.
Check if the EEPROM chip is
Remove the EEPROM and
plugged-in correctly.
re-insert. If the problem persists,
replace control board.
Replace control board.
Keep hands placed on
hand pulse plates until the
result is displayed.
11
EN
FR
ES
IT
RU
UK
SV
FI
www.energetics.eu