INSTALLATION INSTRUCTIONS
7. Use the included anchors to install the
controller. For best cooling, attach to wall. The
controller must be installed at least 3 ft. above
the sump basin.
8. Place the battery inside the battery box and connect
the leads from the controller to the battery terminals.
Connect positive (+) lead to positive terminal on the
battery and black negative (-) lead to the negative
battery terminal.
NOTE: If wires are not connected properly, a loud,
constant audible alarm will sound until the leads are
attached to the correct terminals.
9. Connect backup pump and float leads to the
controller