SCROLL
ESC
4. Confirm.
2.2.1.2 ENTER DOOR LOCK TIME
1. Access programming mode, see page 17.
2. Select:
settings/system
parameters/door lock time.
3. Enter the desired value:
RANGE = 1 - 8 sec.
4. Confirm.
2.2.1.3 ENTER RESET TIME
1. Access programming mode, see page 17.
2. Select:
settings/system
parameters/reset time.
3. Enter the desired value.
RANGE = 1 - 10 sec.
4. Confirm.
2.2.1.4 VIEW
1. Access programming mode, see page 17.
2. Select:
settings/system
parameters/view.
» Reproduces the parameter values: audio time, door
lock time and reset time.
AUDIO TIME
DOOR LOCK TIME
RESET WAIT TIME
2.2.1.5 ADVANCED OPTIONS
2.2.1.5.1 LOCK ON SE
A) TYPE
Allows setting of the door lock type on the SE output of
the speaker module
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/type.
3. Choose between:
AC (default)
AC PLUS
DC
4. Confirm.
TYPE
*AC
AC PLUS
DC
OK
SCROLL
B) CONFIRMATION TONE
Allows enabling/disabling of the door lock confirmation
tone on the speaker module
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/confirmation tone.
3. Choose between:
YES
NO
22 22
VALUE IN SECS
10
OK
CANC
parameters/speaker
parameters/speaker
parameters/speaker
010
02
10
SIMPLEBUS
OK
ESC
4. Confirm.
C) STANDBY LOCK REL.
Allows enabling/disabling of the standby lock release on
the speaker module
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/standby lock rel.
3. Choose between:
YES (default)
NO
4. Confirm.
D) VIEW
Allows viewing of the door lock parameters on the SE
output of the speaker module
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/lock on SE/view.
» Reproduces the parameter values: type, confirmation tone,
standby lock release.
TYPE
CONFIRMATION TONE
STANDBY LOCK REL.
2.2.1.5.2 RELAY CONTACT
A) ACTUATOR FUNCTION
Allows enabling/disabling of the actuator function on the
relay contact
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/actuator function.
3. Choose between:
YES
NO
4. Confirm.
B) IN PARALLEL TO SE
Allows enabling/disabling of the relay contact in parallel
to the speaker module SE output
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/in parallel to SE.
3. Choose between:
YES
NO
4. Confirm.
C) VIEW
Allows viewing of the relay contact parameters
1. Access programming mode, see page 17.
2. Select: settings/system parameters/speaker parameters/
advanced options/relay contact/view.
» Reproduces the relay contact parameters.
ACTUATOR FUNCTION
ACTIVATION TIME
IN PARALLEL TO SE
AC PLUS
03