operatinG issUe
The forks do not lift to maximum height.
The forks do not raise.
The forks do not descend.
Leaks
The forks descend without being
lowered.
note: do not attempt to repair the pallet truck unless you are trained and authorized to do so.
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
PAGE 3 OF 6
troUbleshootinG
caUses
Not enough hydraulic oil.
Not enough hydraulic oil.
The oil has impurities.
Discharge valve is out of adjustment.
Air in the hydraulic oil.
The rod and the cylinder are deformed resulting
from a seriously unbalanced load.
A part has been broken or deformed resulting from
an unbalanced load.
The setting screw is not in the correct position.
Seals worn out or damaged.
Some parts may be cracked or worn out.
Impurities in the oil cause the discharge valve to fail
to close.
Air in the oil.
Seals worn or damaged.
Discharge valve is out of adjustment.
1-800-295-5510
uline.com
recoMMendations
Add more oil.
Add more oil.
Change the oil.
Adjust the setting screw as noted in
Operation.
Expel the air as noted in Maintenance.
Replace the rod and/or cylinder.
Repair or replace component.
Adjust the setting screw as noted in
Operation.
Replace seals with new ones.
Check and replace with new ones.
Change the oil.
Expel the air as noted in Maintenance.
Replace with new ones.
Adjust the setting screw as noted in
Operation.