Setting The Pump - Grundfos UPLM 25-105 130 AUTO REM Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
English

2. Setting the pump

MW-IMG4-7637025-01
23/09/2019- 7637025-03
MW-IMG2-7637025-01
Flashing Fast
PP1
PP2
PP3
PPAA
Flashing Slow
Flashing Slow
Flashing Slow
CP1
CP2
CP3
CPAA
The user interface allows to select between 6 control
curves in 2 control modes:
- 3 proportional pressure curves (PP)
- 3 constant pressure/power curves (CP)
Serial curve setting :
PP1
PP2
CPAA
CP3
Factory presetting :
Proportional pressure curve (PP2):
- Push the button for 2 seconds:
=> Pump goes to setting mode and
LED starts flashing.
- With each push, the setting changes:
=> LED 1-2-3 are permanently on, and
then the control curve and mode is changed.
- Flashing mode:
=> Fast: Proportional pressure
=> Slow: Constant pressure/power
- After 10 seconds not pushing the button:
=> Setting is adapted.
=> Pump returns to operating mode.
- LED 1 or 2 or 3 is permanently on:
=> Pump is running with the selected curve
and mode.
PP3
PPAA
CP2
CP1
MW-IMG3-7637025-01
7