CHARGING FUNCTION IUIO
This function enables to charge lead traction batteries for forklift truck, fork lift, industrial floor cleaning machine, with batteries from
35 Ah to 180 Ah. To connect the charger, process as below:
1. Directly on the battery, use the standard charger clamps
2. On the specific charger plug, replace the clamps at the cable end by the connector adapted to your machine. Respect the polarity
and the current scale.
Find below the charging process :
Phase 1 :
Voltage rise
Phase 2 :
Voltage regulation (during 2 hours)
Phase 3 :
Charge end (Floating)
Nb: If the battery stays connected after the the end of the charge, each 72h, Batium 25/24 starts again a charging cycle
to keep the battery 100% charged.
FORCED CHARGE FUNCTION
In case of a deeply discharged battery, (Voltage under 2V), Batium remains in hold and displays:
. A chain of lights on the current screen
. The indicators « battery voltage », « capacity » and « charging curve » are on.
To force thecharge, press 5 seconds on the key (2) until Batium indicates CHE (=check). The charger detects a battery with a
voltage above 0.8 V.
As for the other models, this step is divided into 2 steps:
1. Diagnostic step (battery voltage analysis).
Nb : For 12v or 24 V batteries, during this step, as your battery is discharged, Batium will detect and offer you a 6V voltage. To
validate or adjust the voltage, press (2) (in less than 10 sec after the first press). See anomaly 6.
2. Recovery step (voltage rise). This step may last up to 30 minutes max.
The diagnostic stage is over (CHE), Batium carries on with normal charge. For more information on the charging process, please
refer to the subdivision Charging function IUoU.
SOS RECOVERY FUNCTION
This function concerns all automotive batteries which are deeply discharged (IUoU).
After the battery has been plugged in, BATIUM does a diagnosis of the battery: Light signal « CHE » displayed.
If after 1 minute, the signal "SOS Recovery" flashes, this means the battery is sulfated.
The "SOS Recovery" function, thanks to a specific charge curve, starts a 24 hours recovery cycle.
To activate this function, proceed as following:
1. Disconnect the battery from the mains. (HIGH VOLTAGE RISK)
2. Connect the Batium to the outlet, then turn the device ON.
3. Select the IUoU charge curve.
4. Activate « SOS Recovery » by pressing during 5 seconds the «SOS recovery» key till the light (6) lights up.
5. Select the battery voltage and charging speed.
6. Connect the Batium's clamps on the battery, the desulfation of the battery starts.
Step 1:
Analyze, starting of the desulfatation and restoration of the
battery
Step 2 :
Desulfatation
Step 3 :
End of charge.
PROTECTIONS
The Batium is protected against short-circuits, polarity inversions and engine starts. It has an anti-spark feature which prevents sparks whilst
the battery is connected to the Batium. The Batium will not deliver current if there is no battery detected (no voltage in the clamps).
8
BATIUM 25/24
Voyant allumé
Indicators lit
Affichage
Charging
current
Charging
current
Displaying
Display of the current.
According to the battery behavior, the
current may increase or decrease.
Display of the current
Battery irretrievable
Batterie saved
EN