3.2.2

Dimensioning of the circuit breaker

The circuit breaker must conform to IEC 60898. The let-
through energy (I²t) must not exceed a maximum 80,000
A²s.
Alternatively, a residual current circuit breaker combina-
tion (RCBO) according to EN 61009-1 can be used. The
aforementioned parameters apply for this circuit breaker
combination.
3.2.3

Mains isolation device

The charging station does not have its own main ON/OFF
switch. The protective devices installed in the power sup-
ply system are therefore also used to disconnect the
power supply.

Installation

3.3
See also chapter 4, "Installation" on page 17.
The supplied installation material is intended for mount-
ing the charging station on a masonry or concrete wall.
For installation on a stand, the mounting material is in-
cluded in the scope of delivery of the stand.
u
Take into account the mounting position at the install-
ation location. See Fig: Live Wall mounting.
Remove the drill template at the perforation from the
u
packaging.
u
Mark the four positions of the drill holes at the install-
ation location using the drill template. See Fig: Live
Wallmounting.
u
Drill 4 holes of Ø 8 mm in the marked positions.
NOTE
The central hole should be used for the building wir-
ing system. The hole shown on the left must be used
if the LAN cable is used.
u
Position the bracket over the upper holes and mount
using 2 wall plugs and 2 screws, 6 x 70 mm, T25.
5111233A_ISI_Next
u
Remove the lower cover from the connection area of
the charging station.
Fig. 1
u
Remove the spiral antikink protection from the con-
nection area of the charging station and place it with
the other supplied material.
u
For surface mounting, make a recess for routing the
lead on the back of the charging station using the des-
ignated lateral predetermined breaking points (if ne-
cessary deburr the edge of the break using a round
file).
u
Insert the lead through the designated lead-through
and fit the charging station on the previously mounted
bracket.
u
Mount the charging station using 2 screws,
6 x 90 mm, T25 using the mounting holes in the lower
connection area. Do not exceed the max. torque of
6 Nm.
3.3.1

Connecting the charging cable

u
Push the spiral antikink protection with the threadless
opening forward over the supplied charging cable.
u
Guide the charging cables through the previously pre-
assembled sealing clip.
NOTE
Ensure correct fit of the previously pre-assembled rub-
ber seals in the sealing clip.
Push the charging cable at least 10 mm beyond the
u
upper edge of the clamping area of the strain relief
clamp.
Turn the antikink protection spiral several turns onto
u
the sealing clip.
NOTE
Do not tighten yet.
Fig. 2
Screw in the supplied strain relief clamp in the correct
u
position on the charging cable.
NOTE
The strain relief clamp has two position options for
charging cable versions 11 kW and 22 kW.
Ensure that the "11 kW installed" label for an 11 kW
charging cable is visible.
u
Fit the strain relief clamp in the correct mounting posi-
tion using the supplied self-tapping Torx screws
(6.5 x 25 mm) and tighten to 5.5 Nm. (Attention: Do
not overtighten screws).
The strain relief clamp must be flush when securely
u
screwed in.
NOTE
Perform a tension test on the charging cable to make
sure that the cable cannot move.
u
Screw the antikink protection spiral onto the sealing
clip with a torque of 4 Nm.
u
Using the slot-head screwdriver (3.5 mm), connect the
individual cable ends according to the specification in
the illustration on the right terminal block with the
"out" label.
To do this, insert the screwdriver in the designated up-
u
per opening of the spring relief for the terminal block
and open the clamping spring.
Now insert the individual wire into the designated
u
connection opening of the terminal block (lower
opening).
Charging cable Description
N
Blue
L1
Brown
L2
Black
L3
Grey
PE
Yellow-green
Control cable (CP)
Black-white
u
Then pull the screwdriver out again and perform a
tension test to make sure that the individual wires are
clamped properly and fully.