Guidance and manufacturer's declaration —
electromagnetic immunity — for the AP 8120
The AP 8120 is intended for use in the electromagnetic environment specified below. The
customer or the user of the AP 8120 should assure that it is used in such an environment.
Table 2: Guidance and manufacturer's declaration – electromagnetic immunity
IMMUNITY test
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrical fast
transient/burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
Avaya WLAN 8100 Regulatory Information - WLAN AP 8120 with External Antenna
Guidance and manufacturer's declaration — electromagnetic immunity — for the AP 8120
IEC 60601 test level Compliance level
± 6 kV contact
± 8 kV air
± 2 kV for power
supply lines
± 1 kV for input/
output lines
± 1 kV line(s) to
line(s)
± 2 kV line(s) to earth
<5% UT
(>95% dip in UT) for
0,5 cycle
40% UT
(60% dip in UT) for 5
cycles
70% UT
(30% dip in UT) for 25
cycles
<5% UT
(>95% dip in UT) for
5 s
Electromagnetic
environment –
guidance
Complies
Floors should be
wood, concrete or
ceramic tile. If floors
are covered with
synthetic material,
the relative humidity
should be at least
30%.
Complies
Mains power quality
should be that of a
typical commercial or
hospital
environment.
Complies
Mains power quality
should be that of a
typical commercial or
hospital
environment.
Complies
Mains power quality
should be that of a
typical commercial or
hospital
environment. If the
user of the AP 8120
requires continued
operation during
power mains
interruptions, it is
recommended that
the AP 8120 be
powered from an
uninterruptible power
supply or a battery.
March 2012