Avaya WLAN AP 8120 Manual Del Usuario página 26

Ocultar thumbs Ver también para WLAN AP 8120:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

English
Note:
Assembling the external antenna to the WLAN AP 8120 with External Antenna is completed
through Reverse Polarity SMA (RP-SMA) connectors. The installer should properly torque
the connector using a 5/16 inch torque wrench that is set to 3-5 in·lbf (0.3 to 0.6 N·m) for
brass, and 7-10 in·lbf (0.8–1.1 N·m) for stainless steel connectors. Flats are also provided
on the cable side of the connector assembly so that you use a second wrench to prevent it
rotating and damaging the joint to the cable. Avaya also recommends that you clean out
loose debris from the internal surfaces before connecting.
Warning:
The AP 8120 with External Antenna is designed for indoor use only and must not be used
outdoors.
Warning:
The AP 8120 with External Antenna must be installed by a professional installer. Read and
follow all warning notices and instructions on the product or included in the
documentation.
Laird antenna with arrow showing reverse polarity connector
The mounting bracket is designed to use wall anchors with threaded section diameters ranging
between 3.5mm and 4.5mm. If wall anchors have threaded diameters greater than 3.5mm,
only the two mounting holes marked 'A ' may be used. If wall anchors have threaded diameters
of less than 3.5mm, the holes marked 'A' and the holes marked 'B' may be used. All wall
anchors must have a head diameter of less than 10mm or the wall mounting bracket cannot
be installed over them.
Perform the following procedure to mount a wireless LAN access point on a wall:
26
Avaya WLAN 8100 Regulatory Information - WLAN AP 8120 with External Antenna
Comments? infodev@avaya.com
March 2012

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wlan 8100 serieWlan ap 8120 serie

Tabla de contenido