Regulatory Compliance Statements
Power frequency
(50/60 Hz) magnetic
field
IEC 61000-4-8
Note:
UT is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer's declaration – electromagnetic
immunity – for AP 8120 that are not life-supporting
The AP 8120 is intended for use in the electromagnetic environment specified below. The
customer or the user of the AP 8120 should assure that it is used in such an environment.
Table 3: Guidance and manufacturer's declaration – electromagnetic immunity (for AP
8120 that are not life-supporting)
Immunity test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
18
Avaya WLAN 8100 Regulatory Information - WLAN AP 8120 with External Antenna
3 A/m
IEC 60601 test
Compliance
level
level
3 Vrms
3V
150 kHz to 80 MHz
3 V/m
3 V/m
80 MHz to 2.5 GHz
Comments? infodev@avaya.com
Complies
Power frequency
magnetic fields
should be at levels
characteristic of a
typical location in a
typical commercial or
hospital
environment.
Electromagnetic environment –
guidance
Portable and mobile RF
communications equipment
should be used no closer to any
part of the AP 8120, including
cables, than the recommended
separation distance calculated
from the equation applicable to
the frequency of the transmitter.
Recommended separation
distance
80 MHz to 800 MHz
800 MHz to 2.5 GHz
March 2012