INSTALLATION INSTRUCTIONS (CONTINUED)

Electrical Information

Improperly grounded motors are shock hazards. Make sure all the equipment is properly grounded.
Improper installation of the grounding plug is able to result in a risk of electric shock. When repair or replacement
of the cord or plug is required, do not connect the grounding wire to either flat blade terminal. The wire with
insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Overheating, short circuiting and fire damage will result from inadequate wiring.
Disconnect, tag and lock out power source, then release all pressure from the system before attempting to install,
service, relocate or perform any maintenance.
Damage to the motor from improper electrical voltage or connection will void the warranty.
DO NOT USE AN EXTENSION CORD, USE A LONGER AIR HOSE.
The 120 volt, 15 amp units can be operated on a 120 volt, 15 amp circuit under the following conditions:
1.
No other electrical appliances or lights are connected to the same branch circuit.
2.
Voltage is 120 Volts.
3.
Circuit is equipped with a 15 amp circuit breaker or a 15 amp slow blow fuse type T (For Canada use
Type D).
4.
The length of copper wire between the outlet and circuit breaker is not longer than 40 ft. of
14 AWG or 70 ft. of 12 AWG.
Grounding
Improperly grounded electrical components are shock hazards. Make sure all the components are properly grounded
to prevent death or serious injury.
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for the electric
current. This product is equipped with a cord having a
grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes
and ordinances. Do not use grounding adapter.
Improper use of grounding plug can result in a risk of
elecrical shock. Plug must be plugged into an outlet that is
properly installed and grounded in accordance with local
codes and ordinances by a qualified electrician.
This product comes from the factory ready for use on a nominal
120 volt circuit and has a grounding plug similar to the plug
illustrated in Figure 8. If the listed conditions cannot be met or if
nuisance tripping of the current protection device occurs, it may
be possible to operate the compressor from a 120 volt 20 amp
circuit. See Figure 8.
Check motor data plate for 240 volt compatibility. A 240 volt
unit must be operated on a 240 volt circuit. The cord must only
plug into a 240 volt grounded outlet and may require a new cord and plug. See Figure 9. This product may
be modified to operate at 240V. To do so, a 240V power cord needs to be purchased and installed on the
unit and wired into the pressure switch just like the 120V cord. The panel on the back of the motor needs
to be opened and the flag terminals need to be moved so that the brown wire that is on terminal #1 is on
terminal #7 and the white wire that is on terminal #3 needs to be moved to terminal #1 (where the brown
wire was originally). See Figure 10.
Outlet -
120V/20A
Figure 8
Figure 9
10
Grounded Outlet
Outlet - 120V/15A
Ground Pin
Grounded Outlet
Outlet - 240V
Ground Pin