OPERATING INSTRUCTIONS
Start-up / Break-in Procedure
Do not attach air tools to open end of the hose until start-up is completed and the unit checks okay.
Never disconnect threaded joints with pressure in tank!
1.
Check oil level per the Lubrication Section of this manual.
2.
Open the bottom tank drain valve (see Figure 11). Turn outlet valve to open air flow.
3.
Plug unit in.
4.
Move pressure switch to the AUTO position to run the unit (see Figure 12).
5.
Run the unit for thirty (30) minutes at zero (0) PSI (under no load) to break in pump parts.
6.
Move the pressure switch lever or knob to OFF and turn tank drain valve to shut off air flow. The
compressor is now ready for use.
7.
Change oil after first fifty (50) hours of operation. Perform oil changes every three (3) months or two
hundred (200) hours of run time, whichever comes first.
Figure 11
Compressor Use
It is extremely important to operate the compressor in a clean, well-ventilated area where the surrounding
air temperature will not be more than 100°F. Do not locate the compressor air inlet near steam, paint spray,
sandblast areas or any other source of contamination.

On/Off Cycling of Compressor

Drain tank every day to prevent corrosion and possible injury due to tank damage. Do not operate drain with
more than 40 PSI in tank or drain valve may be damaged. Drain tank of moisture daily using the drain valve
in the bottom of the tank.
Drain liquid from tank daily.
In the AUTO position, the compressor pumps air into the tank. When a shut-off (preset "cut-out") pressure
is reached, the compressor automatically shuts off.
If the compressor is left in the AUTO position and air is depleted from the tank by use of a tire chuck, tool,
etc., the compressor will restart automatically at its preset "cut-in" pressure. When a tool is being used
continuously, the compressor will cycle on and off automatically.
In the OFF position, the compressor will not operate.