This appliance is suited for the commer-
–
cial use, e.g. in hotels, schools, hospi-
tals, factories, shops, offices, and rental
companies.
Device elements
1 Electrodes
2 Suction hose
3 Cable hook
4 Air outlet, working air
5 Suction head lock
6 Impeller
7 Air inlet, motor cooling air
8 Dirt receptacle
9 Suction head
10 Steering roller
11 Suction support
12 Floor nozzle (not included in the deliv-
ery)
13 Suction pipe (not included in the deliv-
ery)
14 Rotary switch for suction hose cross
section
15 Carrying handle
16 Filter cover
17 Filter cover screw
18 Scale of the suction hose cross section
19 Elbow (not included in the delivery)
20 Rotary switch for suction output (min-
max)
21 Indicator lamp
22 Socket
23 Automatic filter dedusting
24 Main switch
25 Flat fold filter
26 Filter dedusting
27 Floor nozzle holder
28 Holder for crevice nozzle
29 Holder for suction pipes
30 Power cord
31 Nameplate
18
Symbols on the machine
WARNING: This appliance con-
tains harmful dust. The emptying
and maintenance, including the
removal of the dust bag, may
only be executed by trained personnel
wearing suitable protection equipment. Do
not switch on until the complete filter sys-
tem has been installed and until the func-
tion of the volume flow control has been
checked.
Note: The spare parts numbers are listed in
the appendix.
Safety instructions
Danger
When the outgoing air is carried back
–
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V
x ventilation rate L
R
mum. Without a specific ventilation
system the following applies: L
Only persons trained in the use of the
–
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
This appliance contains harmful dust.
–
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
– 2
EN
Flat fold filter
Order No.
379.107
Safety filter bag
Order No.
379.115
) at maxi-
W
=1h
.
–1
W