Function
Once the sensor light fixture
has been wired up and
approx. 10 sec.–max. 15 min.
10 – 60 W
10
18.02.2003
9:06 Uhr
fastened to the wall support,
it can be switched on.
a. Lighting controller
(threshold)
The desired light threshold
can be adjusted continu-
ously from about 2 lux to
2,000 lux. The adjusting
screw turned clockwise all
the way equals daytime
operation at approx. 2,000
lux; counter clockwise all
the way equals nighttime
operation at approx. 2 lux.
b. Switch-off delay
(time setting)
The period for which the
fixture should light up can
be adjusted continuously,
from about 10 seconds to
15 minutes. The adjusting
screw turned clockwise all
the way equals minimum
time, approx. 10 seconds;
counter clockwise all the
Infinitely variable bright-
ness control (Watt-o-matic)
The following functions can
be controlled by means of
the dimmer control:
1) Adjusting screw turned
clockwise all the way
means that the sensor
light fixture is switched
off. Only when move-
ment is detected is the
light switched on at full
power.
2) By setting the adjusting
screw between center
position and turned
clockwise all the way,
the brightness of the
fixture in standby mode
can be adjusted continu-
ously between about
Seite 10
Three settings can now be
made on the light fixture's
sensor lens.
(The unit is shipped with a
factory setting for daytime
operation.) When adjusting
the sensor light fixture
detection zone and for a
performance test during
daylight, the adjusting
screw must be turned
clockwise all the way.
way equals maximum time,
approx. 15 minutes. (The
unit is shipped with a fac-
tory setting of the minimum
time.) We recommend set-
ting the unit to the minimum
time when adjusting the
SensorLamp's detection
zone or carrying out a per-
formance test.
10 watts and a maximum
of 60 watts. This means
that when movement is
detected the light swit-
ches from 40 W main-
tained lighting, for
example, to maximum
output (60 W).
3) Adjusting screw of dim-
mer turned counter
clockwise all the way
and adjusting screw of
lighting controller turned
clockwise all the way: in
this setting, the Sensor-
Lamp is constantly on.
If there is an on/off
switch in the circuit, the
sensor light fixture can
be operated as a normal
light fixture.